Siprocess UV600 Continuous Gas Analyzer

SIPROCESS UV600 is an extractive UV gas analyzer that can simultaneously measure up to three components. The measuring principle is based on the molecule-specific absorption of gases in the ultraviolet wavelength range. Radiation of a wavelength appropriate to the measurement is passed through the sample, and the selective absorption which is proportional to the concentration of the measured component is determined.

Notify me on updates of this product 

Availability: Commercially Available

Gregg Meidl
Sales
gregg.meidl@siemens.com
918-662-7409
408 US Hwy 60
Bartlesville, OK 74003
Manufacturer
Siemens Industry, Inc.
Product Name
Siprocess UV600 Continuous Gas Analyzer
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Ultraviolet-Visible;
Application
Emergency Response; Gas Analysis;
Equipment Type
Sensor
Product Synopsis
SIPROCESS UV600 is an extractive UV gas analyzer that can simultaneously measure up to three components. The measuring principle is based on the molecule-specific absorption of gases in the ultraviolet wavelength range. Radiation of a wavelength appropriate to the measurement is passed through the sample, and the selective absorption which is proportional to the concentration of the measured component is determined.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
19 x 15.9 x 6.97 in (483 x 405 x 178 mm)
Weight
<50 lbs.; 37.5 lbs (17 kg)
Power Requirements
AC/DC Line Power; 100 to 120 V AC, 200 to 220 V AC
Transportability
Benchtop/Fixed
Ruggedness
None; drop sensitive
Operating Conditions
Operation: +5 to 45°C (41 to 113° F) Transport and storage: -10 to 70°C (14 to 158° F) Relative humidity: 10 to 95%, non-condensing
Consumables
>$1,000/year; Calibration gas, zero span gas, safety filter, power supply units, 24 V DC, distribution board, FKM hose d = 3/5, length = 1 m, MEDL UV lamp with heater 1, motor flange, motor flange, gas filter with holder, for measurement of NO, SIPROCESS UV600 chamber H = 300 mm, aluminum, calibration chamber with holder for NO, calibration chamber with holder for SO2 and H2S, calibration chamber with holder for NO2, heater with 380 mm long cable, for SIPROCESS UV600: MEDL, chamber, motor flange, moisture sensor, spare parts set - pressure sensor with gasket and O-ring, flow sensor with temperature sensor, diaphragm pump type 123, 24 V DC / 50 Hz, diaphragm assembly, EPDM for types 110-125, and an o-ring for gas pump suspension
Calibration Schedule
Yes
Suggested Routine Maintenance
Minimal, little or no maintenance other than UV lamp
Data Analysis Support Equipment
Second IO module, optional calibration unit, flow monitor, humidity monitor, pressure sensor
Communications Interface
Ethernet, Si-Process-UV-600-specific software tool
Shelf Life
<5 years; 2 years
Unit Cost
$28,000.00
Maintenance Cost
Minimal
Other Chemical Targets
Measures: NO, NO2, SO2 or H2S
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
The sample gases must be fed into the analyzers free of dust. Condensation in the sample chambers must be prevented. Therefore, the use of gas modified for the measuring task is necessary in most application cases.
Start Up Time (From Cold Start To Sample Ready)
1 hr
Response Time (Sample Application To Output)
Continuous (<30 seconds); T90 – up to 10 seconds
Alarm Capability
Yes
Software Control
May be parameterized and operated using a PDM tool. The analyzers can optionally communicate with the Siprom GA software tool that is integrated into the Ethernet via TCP/IP.
Training Required
<1 week training
Training Available
Yes
Manuals Available
Operator’s Manual
Warranties
18 month
IATA Shipping Restrictions
Yes; gases are regulated by IATA