Safeye 700 Open Path Combustible Gas Detector
Detects the gas presence of a wide range of gaseous hydrocarbons, such as alkanes, alkenes (C1-C8), alcohols, LNG, LPG, and ethylene. SafEye 700 consists of an advanced Xenon Flash infrared transmitter (source) and infrared detector (receiver). The system analyzes the absorption of radiation caused by gases in the atmosphere and comparing it to background atmospheric absorption. A single system can monitor line-of-sight up to 460 feet. It’s specifically engineered to perform in harsh installations such as high-velocity airflows, humidity, corrosive gases, and up to 90% beam blockage.
Availability: Commercially Available
| Manufacturer |
| Sensidyne LLP |
| Product Name |
| Safeye 700 Open Path Combustible Gas Detector |
| Detection Category |
| Chemical |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Non-Dispersive Infrared (NDIR); |
| Application |
| Emergency Response; Gas Analysis; |
| Equipment Type |
| Sensor |
| Product Synopsis |
| Detects the gas presence of a wide range of gaseous hydrocarbons, such as alkanes, alkenes (C1-C8), alcohols, LNG, LPG, and ethylene. SafEye 700 consists of an advanced Xenon Flash infrared transmitter (source) and infrared detector (receiver). The system analyzes the absorption of radiation caused by gases in the atmosphere and comparing it to background atmospheric absorption. A single system can monitor line-of-sight up to 460 feet. It’s specifically engineered to perform in harsh installations such as high-velocity airflows, humidity, corrosive gases, and up to 90% beam blockage. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| Detector 8.2 x 5.7 x 6 in (209 x 145 x 153 mm) Source 10 x 5.3 x 6.9 in (254 x 135 x 176 mm) Mount 4.7 x 4.7 x 5.5 in (120 x 120 x 140 mm) |
| Weight |
| <30 lbs.; Detector 9.2 lbs, Source 10.1 lbs, Mount 4.2 lbs |
| Power Requirements |
| AC/DC Line Power; 18-32 VDC |
| Transportability |
| Mounted |
| Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock; MIL-STD-810C method 514.2, procedure VIII For shock meets MIL-STD-810C method 516.1, procedure I For salt meets MIL-STD810C method 509.1 procedure I exposure to 5% salt solution for 48 hours |
| Operating Conditions |
| < 95% Relative Humidity for the operational temperature range -20 to 55°C (operating temperature) -40 to 65°C (storage temperature) |
| Calibration Schedule |
| Yes |
| Data Analysis Support Equipment |
| Tilt mount, commissioning kit, hand-held kit, pole mount, weather cover for the source unit, weather cover for the detector unit |
| Communications Interface |
| RS-485 Modbus output to allow networking to a central monitoring / PC system for local and remote usage. |
| Unit Cost |
| $8,900.00 |
| Maintenance Cost |
| Minimal |
| Other Chemical Targets |
| Detects: gaseous hydrocarbons, such as alkanes, alkenes (C1-C8), alcohols, LNG, LPG, and ethylene |
| Sample Introduction |
| Vapor/Gas |
| Sensitivity/Detection Limits |
| %LEL |
| Known Interferents/Inhibitors |
| Not influenced by solar radiation, hydrocarbon flames and other external IR radiation sources |
| Start Up Time (From Cold Start To Sample Ready) |
| No warm-up time |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds); 3 seconds to T90 |
| Alarm Capability |
| Yes |
| Software Control |
| Commands may be sent, communication is through Modbus protocol |
| Training Required |
| <1 week training |
| Manuals Available |
| Yes |
| Warranties |
| 3 years for complete system, 10 years for Xenon Flash source bulb |