MultiRAE Pro
The MultiRAE Pro multigas monitor combines a PID (Photoionization Detector) with the standard four gases of a confined space monitor (O2, LEL, and two toxic gas sensors) in one compact monitor with sampling pump.
Availability: Commercially Available
| Manufacturer |
| Honeywell Analytics |
| Product Name |
| MultiRAE Pro |
| Detection Category |
| Radiological/Nuclear;Chemical; |
| Detection Principle |
| Sensors;Scintillation Detectors; |
| Detection Method |
| Electrochemical Detection; Photoionization Detection ; |
| Application |
| Emergency Response; Gas Analysis;Personal Radiation Detectors; |
| Product Model Number |
| PGM-6248 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The MultiRAE Pro multigas monitor combines a PID (Photoionization Detector) with the standard four gases of a confined space monitor (O2, LEL, and two toxic gas sensors) in one compact monitor with sampling pump. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent; Hands-on experience |
| Supporting Documentation |
| Docs: Datasheet_MultiRAE20Pro_DS-1068-11_US-EN_LR.pdf; |
| Dimensions |
| 4.6 x 3.0 x 1.9 in (117 x 76 x 235 mm) |
| Weight |
| <5 Lbs.; 31 oz. (0.88 kg) |
| Power Requirements |
| Lithium Battery; NiMH Battery; Alkaline Battery; 3.6 V 3.0 Ah Li ion or 4.8 V 1,4 Ah NiCd battery; 4 AA alkaline battery adapter, field replaceable (10 hr. operating time) |
| Noise Produced |
| Low humming noise during operation, loud audible beeps during startup and shutdown, can be silenced. |
| Transportability |
| Handheld |
| Ruggedness |
| Waterproof/Resistant; Extreme Temperatures/Humidity; Constructed of composite material with weatherproof rubber boot |
| Operating Conditions |
| –20 to 45°C (–4 to 113°F) |
| Consumables |
| >$1,000/year; Sensors, calibration kit, batteries |
| Solvents/Reagents |
| None |
| Calibration Schedule |
| 2-point field calibration for zero and standard reference gas |
| Suggested Routine Maintenance |
| Replacement of sensors and other maintenance as required |
| Available Accessories |
| Battery adapter, calibration adapter, inlet probe, water trap filter, carbon filters, rubber boot with belt clip, carrying case |
| Data Analysis Support Equipment |
| Computer |
| Communications Interface |
| Data download to PC and parameter upload from PC. Wireless data transmission option available. |
| Unit Cost |
| $3,416.00 |
| Maintenance Cost |
| 4-year repair and replacement contract available for $875 |
| Tested For Chemical Agents |
| GB, GD, L, GA, Did not detect VX (but may detect if sample is pulled through a silver fluoride conversion pad) |
| Tested For ITF-25 TIC/TIMs |
| H2S, SO2, Cl2, HCN, NH3, arsine, CS2, ethylene oxide |
| Tested For Explosives |
| Detects LEL of VOC gases |
| Other Chemical Targets |
| All volatile VOCs Does not detect phosgene |
| Radiological Targets |
| Gamma |
| Adaptability |
| No; PID can detect most volatile organic compounds, but must apply a conversion factor for quantitative results. System has replaceable EC cells for customizing to detect specific target analytes. |
| Sample Introduction |
| Vapor/Gas
Radioactive Particle |
| Sensitivity/Detection Limits |
| ppm
0 to 20,000 µRem/h (dose rate) |
| Known Interferents/Inhibitors |
| PID responds to many organic vapors. May false alarm to heavy concentrations of various smokes and engine exhausts. |
| False Positive Rates |
| <5% False Positive and Negative Rate |
| False Negative Rates |
| <5% False Positive and Negative Rate |
| Start Up Time (From Cold Start To Sample Ready) |
| 1 minute |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
| Total Run Time |
| Continuous |
| Alarm Capability |
| Audible, visual and vibrational |
| Software Control |
| Data logger |
| Other Operational Parameters |
| Other operational parameters on vendor website. |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Operator’s manual |
| Warranties |
| Lifetime on unit excluding consumable parts; 1 yr. or 2 yr. on EC sensor depending on type. |
| IATA Shipping Restrictions |
| None; Calibration gas cylinder must be shipped per IATA restrictions for compressed gas. Lithium ion battery restrictions. |