AQ5000 Pro and AQ5001 Pro

The AQ5000Pro and AQ5001Pro IAQ Monitors are single monitoring devices for recording, reporting, charting and analyzing many hazards contributing to poor indoor air quality. Both monitors provide: infra-red sensor, thermometer sensor, capacitive sensor, gas sensor, and linear analog input channel.

Notify me on updates of this product 

Availability: DISCONTINUED

+1 262 567 9157
1060 Corporate Center Drive
Oconomowoc, Wisconsin 53066
USA
www.quest-technologies.com
Manufacturer
Quest Technologies
Product Name
AQ5000 Pro and AQ5001 Pro
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection;
Application
Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The AQ5000Pro and AQ5001Pro IAQ Monitors are single monitoring devices for recording, reporting, charting and analyzing many hazards contributing to poor indoor air quality. Both monitors provide: infra-red sensor, thermometer sensor, capacitive sensor, gas sensor, and linear analog input channel.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
15 x 10.5 x 6 in (38 x 26.7 x 15 cm)
Weight
<5 lbs.; 2 lbs (.9 kg)
Power Requirements
NiMH Battery; Alkaline Battery; AC/DC Line Power; Rechargeable NiMH battery, AA alkaline batteries, AC power adapter
Transportability
Handheld
Operating Conditions
0 to 50°C (32 to 122°F)
Consumables
<$1,000/year; Sensors
Calibration Schedule
Annually
Suggested Routine Maintenance
None
Communications Interface
RS232 Connection
Shelf Life
<5 years; 2 years
Unit Cost
$3,090.00
Maintenance Cost
Annual calibration charge: $335 (Automatic warranty renewal with each calibration)
Tested For ITF-25 TIC/TIMs
Carbon dioxide, and your choice of oxygen, carbon monoxide, hydrogen sulfide, nitrogen dioxide, nitric oxide, hydrogen cyanide, or ammonia sensors.
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
SO2 sensor may produce a negative response when exposed to NO2.
Start Up Time (From Cold Start To Sample Ready)
1 to 2 minutes start up time
Response Time (Sample Application To Output)
<5 minutes; 2 minutes
Alarm Capability
No
Software Control
Data log can be transferred to PC
Training Required
<1 day training
Manuals Available
Yes
Warranties
1 year
IATA Shipping Restrictions
Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions.
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: