AP4C-V
The AP4C-V is a ready-to-mount system for vehicles or critical infrastructures that provides real-time detection of all chemical threats in either vapor, gas and aerosol form.
The AP4C-V is particularly suitable for use in rough conditions. It is intended to be used in fixed position on detection beacons or on vehicles (mobile shelters, armored vehicles...). The added air vein makes an efficient dust filtration and allows external air speed up to 110 Km/h. The AP4C-V has an 24 h autonomy and protects your assets thanks to its extremely short response time and unrivaled detection performance.
The AP4C-V is a monitor equipped with flameproof protection at burner input and at air circulator
Availability: Commercially Available
Manufacturer |
| Proengin, Inc. |
Product Name |
| AP4C-V |
Detection Category |
| Chemical; |
Detection Principle |
| Elemental Analysis; |
Detection Method |
| Flame Spectroscopy; |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The AP4C-V is a ready-to-mount system for vehicles or critical infrastructures that provides real-time detection of all chemical threats in either vapor, gas and aerosol form.
The AP4C-V is particularly suitable for use in rough conditions. It is intended to be used in fixed position on detection beacons or on vehicles (mobile shelters, armored vehicles...). The added air vein makes an efficient dust filtration and allows external air speed up to 110 Km/h. The AP4C-V has an 24 h autonomy and protects your assets thanks to its extremely short response time and unrivaled detection performance.
The AP4C-V is a monitor equipped with flameproof protection at burner input and at air circulator |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: AP4C_V Information.pdf; AP4C_V Data Sheet.pdf; |
Dimensions |
| 13.5 x 4.17 x 6.81 in (342 x 106 x 173 mm) |
Weight |
| <30 lbs.; 8.8 lbs (4 kg) |
Power Requirements |
| AC/DC Line Power; AC power: 24 VDC x 3 A max |
Noise Produced |
| Low humming sound |
Transportability |
| Mounted |
Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock; EMC requirements |
Operating Conditions |
| –32 to 50°C (-26 to 122°F)
Operational altitude: 10,000 feet
93% HR (non-condensing) |
Consumables |
| <$1,000/year; refilling or replace for the Hydrogen cylinder (12 hours autonomy) |
Calibration Schedule |
| Self-test on startup requires no user input |
Suggested Routine Maintenance |
| 24 hours with 2 Hydrogen cylinders
Recommended preventive maintenance of 1 year |
Available Accessories |
| Control box
Hydrogen storage device |
Data Analysis Support Equipment |
| Computer |
Communications Interface |
| RS 485; Souriau® |
Expected Operational Life |
| 10 years |
Shelf Life |
| >5 years |
Maintenance Cost |
| No maintenance until 1,000 hours of operation or every 1 years. No maintenance required for 10 years if in storage. |
Tested For Chemical Agents |
| Yes |
Tested For ITF-25 TIC/TIMs |
| Yes |
Other Chemical Targets |
| Any chemical that contains target elements will produce a response (P, HNO bond, As and/or S). |
Adaptability |
| Not applicable; Elemental analysis performs on any threats containing P, S, As, HNO, within LOD limits; Elemental analysis do not use librairy |
Sample Introduction |
| Liquid; Vapor/Gas; Solid |
Sensitivity/Detection Limits |
| µg; ppb |
Known Interferents/Inhibitors |
| Any chemical that contains target elements will produce a response (P, HNO bond, As and/or S). |
Start Up Time (From Cold Start To Sample Ready) |
| 2 min for temperatures between 0 and 35°C (32°F to 95°F)
4 min for temperatures superior 35°C (95°F)
15 min for temperatures inferior 0°C (32°F) |
Response Time (Sample Application To Output) |
| Continuous (vapor, gas, aerosols) (<30 seconds); Custom times of integration from 1 seconds to 128 minutes |
Alarm Capability |
| Audible and Visual (External) |
Software Control |
| Yes, available separately. The unit will still need to be turned on manually |
Other Operational Parameters |
| Yes |
Training Required |
| <1 day training |
Training Available |
| Vendor training at customer’s facility |
Manuals Available |
| Operator’s Manual |
Warranties |
| 1 year; extended warranties are available |
ITAR/EAR Export Regulations |
| No |
IATA Shipping Restrictions |
| Yes; IATA regulations apply to hydrogen storage devices |