Terra Portable XRD/XRF
The Terra system is a rugged, portable field instrument which uses dual XRD and qualitative XRF technology for earthbound applications. Using a specifically developed direct excitation charge coupled device (CCD) “camera”, Terra is able to collect X-ray photon data for both X-ray diffraction and X-ray fluorescence simultaneously. Typical uses include: Rapid ID of dangerous hazardous materials, explosives, fusing materials & accelerants; non-destructive fingerprinting of drug formulations & precursors; and testing for presence and quantity of foreign or substitute ingredients.
Availability: Commercially Available
| Manufacturer |
| Olympus Scientific Solutions America |
| Product Name |
| Terra Portable XRD/XRF |
| Detection Category |
| Chemical; Explosives |
| Detection Principle |
| Elemental Analysis; |
| Detection Method |
| X-ray Diffraction (XRD); X-ray Fluorescence ; |
| Application |
| Laboratory Analysis; Bulk Analysis; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The Terra system is a rugged, portable field instrument which uses dual XRD and qualitative XRF technology for earthbound applications. Using a specifically developed direct excitation charge coupled device (CCD) “camera”, Terra is able to collect X-ray photon data for both X-ray diffraction and X-ray fluorescence simultaneously. Typical uses include: Rapid ID of dangerous hazardous materials, explosives, fusing materials & accelerants; non-destructive fingerprinting of drug formulations & precursors; and testing for presence and quantity of foreign or substitute ingredients. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| Market Entry Date |
| 2008 |
| User Feedback Sources |
| MRIGlobal hands-on experience |
| Supporting Documentation |
| Docs: Olympus - Terra Portable XRD-XRF.pdf; MRIGlobal - Terra.pdf; |
| Dimensions |
| 19.1 x 15.4 x 7.6 in (48.6 x 39.2 x 19.4 cm) |
| Weight |
| <50 Lbs.; 32 Lbs. (14.5 kg) |
| Power Requirements |
| AC/DC Line Power; Lithium Battery; 110 to 220 VAC, 50 to 60 Hz, 70 W max 4 hr. rechargeable batteries |
| Noise Produced |
| Negligible |
| Transportability |
| Person-Portable |
| Ruggedness |
| Vibration/Shock |
| Operating Conditions |
| -10 to 35°C (14 to 95°F), 10 to 90%, RH noncondensing |
| Consumables |
| <$1,000/year; Mylar windows ($100/set of 10) |
| Calibration Schedule |
| Standardization and test samples are included in the kit for use before sampling |
| Suggested Routine Maintenance |
| Mylar window needs to be replaced approximately every 6 months. User can perform basic preventative maintenance; however, major repair work needs to be done by manufacturer. |
| Available Accessories |
| Spinner sample holder, sample preparation accessories |
| Data Analysis Support Equipment |
| Windows XP, X-Powder software |
| Communications Interface |
| USB, Bluetooth, 802.11b/g for remote control from web browser |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $75,800.00 |
| Maintenance Cost |
| $100 |
| Tested For Explosives |
| Yes |
| Tested For Narcotics |
| Yes |
| Other Chemical Targets |
| Modes available include: Soil, Mining, Alloy, Fluids and Consumer Goods |
| Number of Library Entries |
| Several commercial libraries available |
| Adaptability |
| Yes |
| Sample Introduction |
| Solid |
| Sensitivity/Detection Limits |
| ppm; % |
| Start Up Time (From Cold Start To Sample Ready) |
| 1.5 minutes |
| Response Time (Sample Application To Output) |
| <15 minutes; 5 to 15 minutes |
| Total Run Time |
| Minutes |
| Alarm Capability |
| No |
| Software Control |
| Remote, Onboard, PC |
| Other Operational Parameters |
| XRD range: 5 - 55°, XRF Energy Range: 3 - 25 keV, 250 eV resolution, Sample Size: 15 mg; X-Ray tube voltage: 30kV, X-ray tube power: 10W, X-ray target material: Cu or Co (Cu standard), Sampling: Dry powder is placed into a small chamber. |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Operators Manual, Quick Start Guide |
| Reachback Service |
| No |
| Warranties |
| 1 year all inclusive |
| ITAR/EAR Export Regulations |
| No |
| IATA Shipping Restrictions |
| No |
| Data File Type Format |
| TXT |