1732

The 1732 oxygen transmitter is suitable for gaseous oxygen measurements in a variety of processes. This is the sixth generation of zirconia oxygen transmitters designed and manufactured by Novatech Controls since 1980. This oxygen measurement is based on the world’s strongest zirconia sensor that was developed by the CSIRO’s Department of Materials Science. Novatech Controls holds the exclusive rights to manufacture this unique sensor. This sensor, combined with the state-of-the-art 1732 transmitter, provides the perfect solution for your gaseous oxygen measurement.

Notify me on updates of this product 

Availability: Commercially Available

info@novatech.com.au
+61 3 9585 2833
309 Reserve Road
Cheltenham Victoria Australia 3192
www.novatech.com.au
Manufacturer
Novatech Controls Pty Ltd
Product Name
1732
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection ;
Application
Emergency Response; Gas Analysis;
Equipment Type
Sensor
Product Synopsis
The 1732 oxygen transmitter is suitable for gaseous oxygen measurements in a variety of processes. This is the sixth generation of zirconia oxygen transmitters designed and manufactured by Novatech Controls since 1980. This oxygen measurement is based on the world’s strongest zirconia sensor that was developed by the CSIRO’s Department of Materials Science. Novatech Controls holds the exclusive rights to manufacture this unique sensor. This sensor, combined with the state-of-the-art 1732 transmitter, provides the perfect solution for your gaseous oxygen measurement.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
10.3 x 6.30 x 3.55 in (260 x 160 x 90 mm)
Weight
<30 lbs.; 6.6 lbs (3 kg)
Power Requirements
AC/DC Line Power; 85 VAC to 265 VAC, 50/60 Hz, 5W
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP65, IP64
Operating Conditions
-25 to 55°C (-13 to 121°F); 5 to 95%RH, non-condensing
Consumables
None
Solvents/Reagents
None
Communications Interface
RS-232, RS-485 MODBUS
Shelf Life
>5 years
Tested For Chemical Agents
No
Tested For ITF-25 TIC/TIMs
No
Tested For Explosives
No
Tested For Narcotics
No
Other Chemical Targets
Oxygen
Adaptability
No; cannot detect or add new targets
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; %
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Alarm Capability
Yes
Training Required
<1 day training