1732
The 1732 oxygen transmitter is suitable for gaseous oxygen measurements in a variety of processes. This is the sixth generation of zirconia oxygen transmitters designed and manufactured by Novatech Controls since 1980. This oxygen measurement is based on the world’s strongest zirconia sensor that was developed by the CSIRO’s Department of Materials Science. Novatech Controls holds the exclusive rights to manufacture this unique sensor. This sensor, combined with the state-of-the-art 1732 transmitter, provides the perfect solution for your gaseous oxygen measurement.
Availability: Commercially Available
Manufacturer |
| Novatech Controls Pty Ltd |
Product Name |
| 1732 |
Detection Category |
| Chemical |
Detection Principle |
| Sensors; |
Detection Method |
| Electrochemical Detection ; |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Sensor |
Product Synopsis |
| The 1732 oxygen transmitter is suitable for gaseous oxygen measurements in a variety of processes. This is the sixth generation of zirconia oxygen transmitters designed and manufactured by Novatech Controls since 1980. This oxygen measurement is based on the world’s strongest zirconia sensor that was developed by the CSIRO’s Department of Materials Science. Novatech Controls holds the exclusive rights to manufacture this unique sensor. This sensor, combined with the state-of-the-art 1732 transmitter, provides the perfect solution for your gaseous oxygen measurement. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 10.3 x 6.30 x 3.55 in (260 x 160 x 90 mm) |
Weight |
| <30 lbs.; 6.6 lbs (3 kg) |
Power Requirements |
| AC/DC Line Power; 85 VAC to 265 VAC, 50/60 Hz, 5W |
Transportability |
| Handheld |
Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP65, IP64 |
Operating Conditions |
| -25 to 55°C (-13 to 121°F); 5 to 95%RH, non-condensing |
Consumables |
| None |
Solvents/Reagents |
| None |
Communications Interface |
| RS-232, RS-485 MODBUS |
Shelf Life |
| >5 years |
Tested For Chemical Agents |
| No |
Tested For ITF-25 TIC/TIMs |
| No |
Tested For Explosives |
| No |
Tested For Narcotics |
| No |
Other Chemical Targets |
| Oxygen |
Adaptability |
| No; cannot detect or add new targets |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm; % |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Alarm Capability |
| Yes |
Training Required |
| <1 day training |