HazMat Kits

Nextteq HazMat Kits offer on-site identification of unknown chemicals. Gastec Gas Sampling Pumps and Detector Tubes are included in each kit. No calibration, batteries, or electrical power are required. A comprehensive decision chart comes with each kit and provides step-by-step directions to identify gases and vapors. Three kits are available: Deluxe HazMat Kit Model STD-101, Deluxe HazMat Kit (without tubes) Model STD-101-1, and Standard HazMat Kit (tubes only).

Notify me on updates of this product 

Availability: Commercially Available

Derrick
+1 813 249 5888 ext 20
8406 Benjamin Road, Suite J
Tampa, FL 33634
USA
www.nextteq.com
Manufacturer
Nextteq LLC
Product Name
HazMat Kits
Detection Category
Chemical
Detection Principle
Colorimetric;
Detection Method
Colorimetric;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
Nextteq HazMat Kits offer on-site identification of unknown chemicals. Gastec Gas Sampling Pumps and Detector Tubes are included in each kit. No calibration, batteries, or electrical power are required. A comprehensive decision chart comes with each kit and provides step-by-step directions to identify gases and vapors. Three kits are available: Deluxe HazMat Kit Model STD-101, Deluxe HazMat Kit (without tubes) Model STD-101-1, and Standard HazMat Kit (tubes only).
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
20 x 16 x 7.5 in (50 x 39 x 19 cm)
Weight
<30 lbs.; 14 lbs (6.4 kg)
Power Requirements
None
Transportability
Person-Portable
Operating Conditions
0 to 40°C (32 to 104°F); 0 to 90% RH.
Consumables
<$1,000/year; Detector tubes and detection papers
Expected Operational Life
Indefinite
Shelf Life
<5 years; 2 years
Unit Cost
$1,416.00
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
48 chemicals, including carbon monoxide, ammonia, benzene, ethyl acetate, hydrogen cyanide, hydrogen sulfide, hydrocarbons, naphtha, Polytec I, Stoddard solvent, and sulfur dioxide.
Other Chemical Targets
Yes
Sample Introduction
Vapor/Gas; Liquid
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
No false positives from gasoline, diesel fuel, aqueous film forming foam (AFFF), burning tires, or burning wood.
Start Up Time (From Cold Start To Sample Ready)
Immediate
Response Time (Sample Application To Output)
<5 minutes; 2 minutes
Total Run Time
Minutes
Alarm Capability
Visual
Training Required
<1 day training
Training Available
Training simulation kits available for safe, realistic training. Highly trained customer support and technical team available to answer questions.
Manuals Available
User manual
Warranties
Pump is warranted for life, tubes for 2 years
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: