CW Sentry

The CW Sentry Chemical Warfare Agent Detector measures the presence of CWAs and select TICs. The wall-mounted unit uses two separate detector arrays—SAW microsensors and an optional configuration of electrochemical cells—to detect nerve and blister agents, as well as TICs including hydride and halogen. An internal fan draws air into the unit, where it is filtered twice to prevent contamination from dust and dirt. The unit measures the air and transmits the results via a variety of methods, including Ethernet fiber optic lines, while also offering wireless functionality.

Notify me on updates of this product 

Availability: Commercially available

Steven Schmidt
Sales Development Manager, Government
steve.schmidt@msanet.com
+1 800 672 2222
1000 Cranberry Woods Drive
Cranberry Township, PA 16066
USA
www.msasafety.com
Manufacturer
Mine Safety Appliances Company (MSA)
Product Name
CW Sentry
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection;Surface Acoustic Wave Detection;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The CW Sentry Chemical Warfare Agent Detector measures the presence of CWAs and select TICs. The wall-mounted unit uses two separate detector arrays—SAW microsensors and an optional configuration of electrochemical cells—to detect nerve and blister agents, as well as TICs including hydride and halogen. An internal fan draws air into the unit, where it is filtered twice to prevent contamination from dust and dirt. The unit measures the air and transmits the results via a variety of methods, including Ethernet fiber optic lines, while also offering wireless functionality.
Availability
Commercially available
Technology Readiness Level (TRL)
9
Market Entry Date
2001
User Feedback Sources
Indifferent/No user feedback
Dimensions
24.75 x 19.5 x 9.5 in (62.9 x 49.5 x 24.1 cm)
Weight
<50 lbs.; 40 lbs (18.1 kg)
Power Requirements
AC/DC Line Power; 90-240 V, 50/60 Hz (60 watts)
Noise Produced
None
Transportability
Benchtop/Fixed
Ruggedness
Extreme Temperatures/Humidity
Operating Conditions
-20 to 50°C (-4 to 122°F), 10 to 95% RH, non-condensing
Consumables
None
Communications Interface
RS-232, Ethernet, fiber optic, and wireless
Expected Operational Life
5 years
Shelf Life
>5 years; Dependent on sensor
Tested For Chemical Agents
GA, GB, GD, GF, HD, HN3
Tested For ITF-25 TIC/TIMs
Yes
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
Dependent on sensor selected
Start Up Time (From Cold Start To Sample Ready)
< 5 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); 30 seconds (SAW sensors), 5 seconds (Electrochemical sensors)
Total Run Time
Seconds
Alarm Capability
Audible and visible
Software Control
Yes
Training Required
<1 week training
Training Available
Yes
Manuals Available
Yes
Warranties
1 year
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: