MSGS 3002 Methane Gas Sensor

Designed for use with Gas Sensing Microsystem, or MGSM3000 Gas Sensing Module. The MSGS-3002 structure consists of a doped tin-oxide (SnO2) thin-film layer over an embedded thin film heater (figure 1). This integrated heater resistance (RH) is used to control the sensitive layer temperature which is necessary for chemisorption reaction mechanisms to properly occur. These mechanisms modify the sensitive layer resistance (RS) by reversible electron charge transfer from surface states to the conduction band.

Notify me on updates of this product 

Availability: Commercially Available

Alain Grisel
alain.grisel@microsens.ch
+41 327 205161
Rue Jaquet-Droz 1 – 2007
Neuchâtel
Switzerland
www.micrsens.ch
Manufacturer
Microsens SA
Product Name
MSGS 3002 Methane Gas Sensor
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Metal Oxide Semiconductor;
Application
Gas Analysis;
Equipment Type
Sensor
Product Synopsis
Designed for use with Gas Sensing Microsystem, or MGSM3000 Gas Sensing Module. The MSGS-3002 structure consists of a doped tin-oxide (SnO2) thin-film layer over an embedded thin film heater (figure 1). This integrated heater resistance (RH) is used to control the sensitive layer temperature which is necessary for chemisorption reaction mechanisms to properly occur. These mechanisms modify the sensitive layer resistance (RS) by reversible electron charge transfer from surface states to the conduction band.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
0.41 x 0.94 in (10.3 x 24 mm)
Weight
<1 lb.
Power Requirements
AC/DC Line Power; Average Power Consumption 40 mW
Transportability
Pocket Size
Operating Conditions
0 to 50°C (operating temperature) -40 to 70°C (storage temperature)
Consumables
<$1,000/year; Calibration gas
Calibration Schedule
Yes. The sensor is calibrated in the measurement range of gas concentration for the application (need (3-4) known mixture of methane with synthetic air
Data Analysis Support Equipment
MGSM3000 Gas Sensing Module, Gas Sensing Microsystem
Communications Interface
When used with “Microsystem,” RS-232 interface with laptop or PC
Unit Cost
$5.25
Other Chemical Targets
Presently available only as a methane gas sensor
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
Avoid high moisture conditions, avoid overheating sensor
Response Time (Sample Application To Output)
Continuous (<30 seconds); 90% signal level < 30 seconds
Software Control
Yes
Training Required
<1 week training
Manuals Available
Application notes are available
Warranties
Yes, but unspecified
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: