Compact Sensor

Membrapor manufactures a wide range of gas sensors for a variety of different applications, including fixed-point detection systems, personal safety monitors, flue gas analyzers and breath checkers. These electrochemical sensors are direct replacements available to OEMs for monitoring toxic gases such as ammonia, carbon monoxide, hydrogen, nitrogen oxide, nitrogen dioxide, chlorine, sulfur dioxide, hydrogen chloride, ozone, phosphine, silane, perchlorate, formaldehyde, ethene, hydrogen sulfide and hydrogen cyanide. Membrapor is an independent, Swiss sensor manufacturer.

Notify me on updates of this product 

Availability: Commercially Available

info@membrapor.ch
+41 433 117 200
Birkenweg 2 8304
Wallisellen /Zurich
Switzerland
www.membrapor.ch
Manufacturer
Membrapor AG
Product Name
Compact Sensor
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection ;
Application
Emergency Response; Gas Analysis;
Equipment Type
Sensor
Product Synopsis
Membrapor manufactures a wide range of gas sensors for a variety of different applications, including fixed-point detection systems, personal safety monitors, flue gas analyzers and breath checkers. These electrochemical sensors are direct replacements available to OEMs for monitoring toxic gases such as ammonia, carbon monoxide, hydrogen, nitrogen oxide, nitrogen dioxide, chlorine, sulfur dioxide, hydrogen chloride, ozone, phosphine, silane, perchlorate, formaldehyde, ethene, hydrogen sulfide and hydrogen cyanide. Membrapor is an independent, Swiss sensor manufacturer.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
1.3 x .79 in (32 x 20 mm)
Weight
<1 lb.; 13 g
Transportability
Pocket Size
Operating Conditions
5 to 20°C (storage temperature) -20 to 45°C (temperature) Atmospheric +/- 10% (pressure) 15 – 90% Relative Humidity, non-condensing
Shelf Life
<5 years; 3 Years
Unit Cost
$170.00
Other Chemical Targets
Bromine, Ethene, Formaldehyde, Ethylene Oxide, Chlorine, Carbon Monoxide, Hydrogen, Hydrogen Peroxide, Hydrogen Sulfide, Hydrogen Bromide, Hydrogen Chloride, HCN, Ammonia, Nitric Oxide, Nitrogen Dioxide, Oxygen, Ozone, Phosphine, Silane, Sulfur Dioxide
Sample Introduction
Vapor/Gas
Known Interferents/Inhibitors
Has interfering gases see data sheet for specifics
Start Up Time (From Cold Start To Sample Ready)
Would depend on housing
Response Time (Sample Application To Output)
<1 minute; T(90) <35 seconds
Alarm Capability
Only has signal output
Training Required
<1 hour training
Manuals Available
Yes – Spec sheets
Warranties
12 months from day of dispatch