SpinSolve
The SpinSolve is a 42.5 MHz proton (1H) NMR spectrometer. The permanent magnet design provides a high performance, compact and robust instrument that can fit on a typical chemistry workbench. The magnet does not require expensive cryogens and the fringe magnetic field is contained completely inside the spectrometer.
Availability: Commercially Available
Dr. Andrew Coy
+64 (4) 920-7671
32 Salamanca Road
Wellington, New Zealand
|
|
www.magritek.com
| Manufacturer |
| Magritek |
| Product Name |
| SpinSolve |
| Detection Category |
| Chemical |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Nuclear Magnetic Resonance ; |
| Application |
| Laboratory Analysis; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The SpinSolve is a 42.5 MHz proton (1H) NMR spectrometer. The permanent magnet design provides a high performance, compact and robust instrument that can fit on a typical chemistry workbench. The magnet does not require expensive cryogens and the fringe magnetic field is contained completely inside the spectrometer. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 23 x 17 x 16 in (580 x 430 x 400 mm) |
| Weight |
| >50 lbs.; 121 lbs (55 kg) |
| Power Requirements |
| AC/DC Line Power; 100-240 V, 50-60 Hz, no battery |
| Transportability |
| Benchtop/Fixed; Small Footprint |
| Ruggedness |
| None; Due to the tuned components of the internal sample probe dropping equipment is not recommended. |
| Operating Conditions |
| 20 °C (68°F) , 20 to 80% RH, non-condensing |
| Consumables |
| <$1,000/year; Solvents (deuterated) Standard glass, 5 mm NMR tubes |
| Solvents/Reagents |
| Deuterated solvents appropriate for target |
| Calibration Schedule |
| Application dependent |
| Suggested Routine Maintenance |
| User may need to shim magnet |
| Available Accessories |
| System can be configured for Proton, Carbon-13, and Fluorine 19. |
| Data Analysis Support Equipment |
| Computer, mNova NMR software |
| Communications Interface |
| USB |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $8,900.00 |
| Maintenance Cost |
| Monthly lease (minimum 3 months) |
| Tested For Chemical Agents |
| Chemical agents that have protons (1H) can be detected |
| Tested For ITF-25 TIC/TIMs |
| TIC/TIM that have protons (1H) can be detected |
| Tested For Explosives |
| Explosives (nitroaromatics, organic peroxides) that have protons (1H) can be detected |
| Tested For Narcotics |
| Yes |
| Other Chemical Targets |
| Chemicals that have protons (1H) can be detected |
| Sample Introduction |
| Liquid; Solid |
| Sensitivity/Detection Limits |
| µg |
| Known Interferents/Inhibitors |
| Mixtures containing molecules each with protons will lead to spectra that will need some expert interpretation |
| Start Up Time (From Cold Start To Sample Ready) |
| < 1 hour |
| Response Time (Sample Application To Output) |
| <5 minutes; 10 sec to minutes |
| Total Run Time |
| 10 sec to minutes |
| Alarm Capability |
| No |
| Software Control |
| Controlled by software that runs on a separate PC 1-year license for Mestrelab Mnova software for advanced data analysis capability |
| Other Operational Parameters |
| 50% linewidth < 1 Hz, 0.55% linewidth < 40 Hz, 10:1 S/N for 0.1% ethylbenzene single scan |
| Training Required |
| <1 week training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Reachback Service |
| No |