Innova 1412i Multigas Monitor

The Innova 1412i is a quantitative gas monitor based on photoacoustic infrared detection. Optical filters (up to 5 + water vapor) allow the 1412i to selectively measure the concentration of up to 5 component gases and water vapor in air. Detection limits are gas-dependent but are typically in the 10-² ppm region. Photoacoustic detectors are highly sensitive, stable, and have a wide dynamic range, but are relatively non-specific and are not recommended for identification of unknowns.

Notify me on updates of this product 

Availability: DISCONTINUED

Andrew Hammell
+1 714 974 5560
1312 West Grove Avenue
Orange, California 92865–4134
USA
www.gasanalyzers.com
Manufacturer
LumaSense Technologies, Inc.
Product Name
Innova 1412i Multigas Monitor
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Photoionization Detection;
Application
Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The Innova 1412i is a quantitative gas monitor based on photoacoustic infrared detection. Optical filters (up to 5 + water vapor) allow the 1412i to selectively measure the concentration of up to 5 component gases and water vapor in air. Detection limits are gas-dependent but are typically in the 10-² ppm region. Photoacoustic detectors are highly sensitive, stable, and have a wide dynamic range, but are relatively non-specific and are not recommended for identification of unknowns.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
6.9 x 15.6 x 11.8 in (18 x 40 x 30 cm)
Weight
<30 lbs.; 19.8 lbs (9 kg)
Power Requirements
AC/DC Line Power; Lithium Battery; 100 to 240 V (50 to 400 Hz), battery powered (optional)
Transportability
Person-Portable
Operating Conditions
5 to 40°C (41 to 104°F)
Consumables
>$1,000/year; Particulate filters
Calibration Schedule
Semiannual
Suggested Routine Maintenance
Particulate filters must be changed as required
Data Analysis Support Equipment
PC, software
Communications Interface
RS-232, USB, ethernet
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$41,600.00
Maintenance Cost
Optical filter replacements are $3,300
Tested For Chemical Agents
GB, VX, HD
Other Chemical Targets
VOCs (over 300 listed detection limits on vendor website)
Adaptability
Yes
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
Automatically compensates for interferences caused by environmental fluctuations
Start Up Time (From Cold Start To Sample Ready)
< 30 minutes
Response Time (Sample Application To Output)
<1 minute
Total Run Time
< 5 minutes
Alarm Capability
Audible
Software Control
Control from front panel or PC connected via RS232
Other Operational Parameters
Optical filters are required to measure target chemical optical wavelengths and to minimize signal from interfering compounds. An internal filter wheel holds up to five filters.
Training Required
<1 week training
Training Available
Yes
Manuals Available
User's Manual
Warranties
1 year