Andros 6500

Designed for use with ANDROS Pneumatics Package for 6500 Series. The LumaSense 6500 uses a pulsed infrared source. The Non-Dispersive Infrared (NDIR) system measures gases, communicates with the host via RS232 or USB and allows user-defined TTL outputs, as well as analog and tachometer inputs which can be integrated into the data output stream for user convenience.

Notify me on updates of this product 

Availability: Commercially Available

Gloria Youell
info@lumasenseinc.com
(408) 235-3878
3301 Leonard Court
Santa Clara, CA 95054
www.lumasenseinc.com/EN/
Manufacturer
LumaSense Technologies, Inc.
Product Name
Andros 6500
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Infrared (IR) Spectroscopy ;
Application
Gas Analysis;
Equipment Type
Sensor
Product Synopsis
Designed for use with ANDROS Pneumatics Package for 6500 Series. The LumaSense 6500 uses a pulsed infrared source. The Non-Dispersive Infrared (NDIR) system measures gases, communicates with the host via RS232 or USB and allows user-defined TTL outputs, as well as analog and tachometer inputs which can be integrated into the data output stream for user convenience.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
7.6 x 2.9 x 2.0 in (191.8 x 73.7 x 50.3 mm)
Weight
<1 lb.; 0.66 lb (0.3 kg)
Power Requirements
AC/DC Line Power; 12 VDC nominal (9 to 16)
Transportability
Pocket Size
Operating Conditions
0 to 50°C (32 to 122°F); <95% RH, -300 to 3000 m (operating altitude)
Consumables
<$1,000/year; Membrane cap replacement and refilling, calibration standards
Calibration Schedule
No, factory calibration should last for life
Available Accessories
Optional BOD Accessory Kit, pH electrode, conductivity electrode, dissolved oxygen electrode. Pump, solenoid/valve, tubing, power supply
Communications Interface
RS232 and USB outputs, customer may need to write their own program to communicate with the 6500. 6500 Host program is available through the manufacturer, but does not have alarm limits (only data)
Unit Cost
$901.00
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; %
Known Interferents/Inhibitors
Other hydrocarbons could interfere, depending on the wavelength
Start Up Time (From Cold Start To Sample Ready)
30 minutes
Response Time (Sample Application To Output)
<1 minute
Software Control
Uses HachLink Communications Software
Other Operational Parameters
This is just the gas analyzer and it’s missing the pump, solenoid, power supply, and running software. The missing parts would require design and assembly by the customer.
Training Required
<1 week training
Manuals Available
Yes
Warranties
1 year