Ludlum Geiger-Muller Counters

The Ludlum line of Geiger-Muller Counters are gamma exposure ratemeters equipped with an internally housed, energy compensated GM detector that measures over the range of 0 to 10 Sv/h (model 2242) or 0 to 200 µSv/h (model 2401-EC2A).

Notify me on updates of this product 

Availability: Commercially Available

Jeff Anspaugh
jeff@degtech.com
+1 317 512 0010
PO BOX 810
Sweetwater, Texas 79556
USA
ludlum@ludlums.com
+1 800 622 0828
www.ludlums.com
Manufacturer
Ludlum Measurements, Inc.
Product Name
Ludlum Geiger-Muller Counters
Detection Category
Radiological/Nuclear;
Detection Principle
Geiger-Muller Detectors;
Detection Method
Geiger-Muller Detectors;
Application
Survey Meter;Personal Radiation Detectors;
Product Model Number
2242, 2401-EC2A
Equipment Type
Instrument
Product Synopsis
The Ludlum line of Geiger-Muller Counters are gamma exposure ratemeters equipped with an internally housed, energy compensated GM detector that measures over the range of 0 to 10 Sv/h (model 2242) or 0 to 200 µSv/h (model 2401-EC2A).
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: Ludlum Measurements-Ludlum Geiger-Muller Counters-M3005.pdf; Ludlum Measurements-Ludlum Geiger-Muller Counters-M6.pdf; Ludlum Measurements-Ludlum Geiger-Muller Counters-M5.pdf;
Dimensions
Model 2242: 6.5 x 3.5 x 8.5 in (16.5 x 8.9 x 21.6 cm) Model 2401-EC2A: 1.8 x 3.3 x 5.3 in (4.6 x 8.4 x 13.5 cm)
Weight
<5 lbs.; Model 2242: 3.5 lbs (1.6 kg) Model 2401-EC2A: 0.9 lb (0.4 kg)
Power Requirements
Alkaline Battery; Model 2242: Two D-cell batteries (200 hours). Model 2401-EC2A: 9 V
Transportability
Pocket Size
Ruggedness
Extreme Temperatures/Humidity; Model 2242: Rugged. Cast and drawn aluminium with beige powder coat, splashproof. Model 2401-EC2A: field deployable
Operating Conditions
–30 to 50°C (-22 to 122°F)
Consumables
None
Calibration Schedule
Internal calibration
Suggested Routine Maintenance
General cleaning and battery replacement
Available Accessories
Model 2242: Wrist and Shoulder strap Model 2401-EC2A: belt clip, handle, case, wrist strap
Data Analysis Support Equipment
Model 2242: Software
Communications Interface
Model 2242: RS-232
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$1,122 to $2,500
Radiological Targets
Gamma
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
Sv; µSv; mR; Model 2242: 0 to 10 Sv/h (0 to 1000 mR/hr). Model 2401-EC2A: 0 to 200 µSv/h .
False Positive Rates
15 %
Start Up Time (From Cold Start To Sample Ready)
< 2 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); < 4 seconds
Total Run Time
Continuous monitor
Alarm Capability
Audible and visual
Software Control
On-board, PC (model 2242)
Other Operational Parameters
Energy range: 60 keV to 3 MeV
Training Required
<1 day training
Manuals Available
Yes
Warranties
1 year, extended warranty available
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: