IQ-1000 Portable Gas Monitor

The IQ-1000 accepts electrochemical, catalytic bead, and solid-state sensors. The IQ-1000 accepts and simultaneously displays the readings of up to 4 sensors. The IQ-1000’s “Gas Search” feature allows you to use the Mega-Gas sensor to scan an area for hazardous gases.

Notify me on updates of this product 

Availability: Commercially Available

Tom Chou
tom.chou@intlsensor.com
+1 800 478 4271
3 Whatney
Irvine, CA 92618-2824
www.intlsensor.com
Manufacturer
International Sensor Technology
Product Name
IQ-1000 Portable Gas Monitor
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection; Solid-State Detectors; Catalytic Bead Sensor ;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The IQ-1000 accepts electrochemical, catalytic bead, and solid-state sensors. The IQ-1000 accepts and simultaneously displays the readings of up to 4 sensors. The IQ-1000’s “Gas Search” feature allows you to use the Mega-Gas sensor to scan an area for hazardous gases.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
9.0 x 4.5 x 5.4 in (23 x 11 x 14 cm)
Weight
<30 lbs.; 6 lbs (2.7 kg)
Power Requirements
Alkaline Battery; NiMH Battery; 6 ‘D’ size alkaline or nickel cadmium batteries
Transportability
Person-Portable
Ruggedness
None; drop sensitive
Operating Conditions
0 to 50°C (32 to 122°F) ; 0 to 95% RH, non-condensing
Consumables
<$1,000/year; Filters
Calibration Schedule
Factory calibration every 6 to 12 months
Suggested Routine Maintenance
Filters once a year
Available Accessories
Data logging
Data Analysis Support Equipment
“EINSTEIN” data management PC software
Communications Interface
RS-232 port
Shelf Life
<1 year
Unit Cost
$4,000.00
Maintenance Cost
Factory calibration $40
Tested For ITF-25 TIC/TIMs
Non-specific detection of over 100 toxic/combustible gases and vapors. Full listing of detectable chemicals is available on vendor’s website.
Other Chemical Targets
Yes
Adaptability
No; custom user library capability from pre-programmed chemicals
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
Many opportunities for false alarm, but interferents are not specified. Sensors can also be overloaded, causing them to stop functioning properly.
Start Up Time (From Cold Start To Sample Ready)
1 minute
Response Time (Sample Application To Output)
<5 minutes; 45 to 90 seconds
Total Run Time
Continuous
Alarm Capability
Audible and visual
Software Control
PC
Training Required
<1 day training
Training Available
Yes
Manuals Available
Operator’s manual
Reachback Service
No
Warranties
Instrument 1 year, sensors 3 years
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: