M40 Multi-Gas Monitor
M40 is a multi-gas monitor capable of detecting CO, H2S, O2, and combustible gases for a wide variety of hazardous and confined space applications. The M40 is housed in an impact-resistant case to provide durability in harsh environments.
Availability: DISCONTINUED
+1 412 788 4353
1001 Oakdale Road
Oakdale, PA 15071
USA
|
|
www.indsci.com
| Manufacturer |
| Industrial Scientific Corporation |
| Product Name |
| M40 Multi-Gas Monitor |
| Detection Category |
| Chemical |
| Detection Principle |
| Sensors; |
| Detection Method |
| Electrochemical Detection; |
| Application |
| Gas Analysis; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| M40 is a multi-gas monitor capable of detecting CO, H2S, O2, and combustible gases for a wide variety of hazardous and confined space applications. The M40 is housed in an impact-resistant case to provide durability in harsh environments. |
| Availability |
| DISCONTINUED |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 4.30 × 2.45 × 1.37 in (10.9 x 6.2 x 3.5 cm) |
| Weight |
| <1 lb.; 8.6 oz (244 g) |
| Power Requirements |
| Lithium Battery; Rechargeable lithium-ion integral battery |
| Transportability |
| Pocket Size |
| Ruggedness |
| Extreme Temperatures/Humidity; High visibility, impact resistant composite |
| Operating Conditions |
| –20 to 50°C (–4 to 122°F) |
| Consumables |
| <$1,000/year; Calibration gas |
| Calibration Schedule |
| Yes |
| Available Accessories |
| Sample pumps, Datalink, carrying case, charger, belt clip, suspender clip |
| Communications Interface |
| Yes |
| Shelf Life |
| <5 years; 4 years |
| Unit Cost |
| $595.00 |
| Maintenance Cost |
| 4 gas calibration kit $200 to $253 every 8 to 12 months and a regulator for $150 |
| Tested For ITF-25 TIC/TIMs |
| The M40 is available in a 1-, 2-, 3-, or 4-gas configuration including oxygen, hydrogen sulfide, carbon monoxide, and combustibles/hydrocarbons |
| Sample Introduction |
| Vapor/Gas |
| Sensitivity/Detection Limits |
| ppm; %LEL |
| Known Interferents/Inhibitors |
| Many chemicals could potentially cause a false alarm. |
| Start Up Time (From Cold Start To Sample Ready) |
| 20 seconds |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds); 10 to 20 seconds |
| Alarm Capability |
| Audible, visual and vibrational |
| Software Control |
| Yes |
| Other Operational Parameters |
| . |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Warranties |
| 2 years |
| ITAR/EAR Export Regulations |
| Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions. |
| IATA Shipping Restrictions |
| Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions. |