iBRID MX6

The iBRID MX6 simultaneously monitors 1 to 6 gases, with 25 sensor options. The iBRID uses electrochemical sensors, IR sensors, and photoionization detection. Sampling can be done using either a diffusion mode or by internal sampling pump versions.

Notify me on updates of this product 

Availability: Commercially Available

+1 412 788 4353
1001 Oakdale Road
Oakdale, PA 15071
USA
www.indsci.com
Manufacturer
Industrial Scientific Corporation
Product Name
iBRID MX6
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection; Photoionization Detection ;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The iBRID MX6 simultaneously monitors 1 to 6 gases, with 25 sensor options. The iBRID uses electrochemical sensors, IR sensors, and photoionization detection. Sampling can be done using either a diffusion mode or by internal sampling pump versions.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
5.3 x 3.05 x 1.7 in (13.5 x 7.7 x 4.3 cm)
Weight
<1 lb.; 14.4 oz (409 g)
Power Requirements
Lithium Battery; Alkaline Battery; Rechargeable lithium-ion battery pack (24 hours) Rechargeable, extended-range lithium-ion battery pack(36 hours typical) Replaceable AA alkaline battery pack (10.5 hours)
Noise Produced
95 db
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Rugged design and construction provides exceptional durability and immersion protection in the harshest industrial environments
Operating Conditions
–20 to 55°C (–4 to 131°F), 15 to 95% RH
Consumables
<$1,000/year; Sensors, batteries, filters
Calibration Schedule
Performed manually by the user
Suggested Routine Maintenance
Minimal; pump can be clogged if filters aren’t used in dusty environments
Available Accessories
Docking station, sampling pumps, datalink assembly, battery chargers, battery packs, carrying cases.
Data Analysis Support Equipment
Docking station and I-net Ready (An instrument management system)
Communications Interface
Docking Station using a cross over or Ethernet cable
Shelf Life
<5 years; Some sensors expire in 18 to 24 months. Some sensors last 3 to 5 years.
Unit Cost
$2,765.00
Maintenance Cost
Replacement of sensors, $150 to $395 each. PID sensor is $600
Tested For ITF-25 TIC/TIMs
Combustible Gases, Hydrogen Sulfide, Nitric Oxide, Chlorine, Sulfur Dioxide, Hydrogen Cyanide, Hydrogen Chloride, Ammonia, Chlorine Dioxide, Phosphine, and VOCs (general)
Other Chemical Targets
Methane, oxygen, carbon monoxide, hydrogen, nitrogen dioxide, carbon dioxide, and VOCs (general)
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
Silicone based products can render the sensors inactive
Start Up Time (From Cold Start To Sample Ready)
4 to 5 minutes
Response Time (Sample Application To Output)
<1 minute; 30 to 40 seconds
Total Run Time
< 7 minutes
Alarm Capability
Audible, visual, and vibratiional
Software Control
PC
Training Required
<1 day training
Training Available
Yes. Online training also available
Manuals Available
Operator’s manual
Warranties
Lifetime
IATA Shipping Restrictions
Compressed gas cylinders must be shipped ground only according to IATA restrictions.