BM25

The BM25 monitors from one to five gases through diffusion or sample draw. Designed for team protection or area surveillance, the unit is most suitable for perimeter monitoring, rig overhauls, and mobile or short-term work in areas where fixed detection systems are not suitable.

Notify me on updates of this product 

Availability: DISCONTINUED

+1 412 788 4353
1001 Oakdale Road
Oakdale, PA 15071
USA
www.indsci.com
Manufacturer
Industrial Scientific Corporation
Product Name
BM25
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The BM25 monitors from one to five gases through diffusion or sample draw. Designed for team protection or area surveillance, the unit is most suitable for perimeter monitoring, rig overhauls, and mobile or short-term work in areas where fixed detection systems are not suitable.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
16.7 x 6.3 x 5.1 in (42 x 16 x 13 cm)
Weight
<30 lbs.; 15 lbs (6.8 kg)
Power Requirements
NiMH Battery; 100 hours
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity
Operating Conditions
–20 to 50°C (–4 to 122°F)
Consumables
<$1,000/year; Calibration gas, sensors
Solvents/Reagents
Calibration gas
Calibration Schedule
Monthly
Suggested Routine Maintenance
Replacement of sensors
Available Accessories
Optional datalink adapter enables the instrument to store or log the recorded gas readings
Data Analysis Support Equipment
PC
Communications Interface
USB Adapter Cable
Expected Operational Life
10 years
Shelf Life
<5 years; Some sensors expire in 18 to 24 months. Some sensors last 3 to 5 years.
Unit Cost
$5,198.00
Maintenance Cost
$150 to $650 depending on the sensor
Tested For ITF-25 TIC/TIMs
O2, CO, H2S, C2H4O, SO2, NO, NO2, HCN, HCl, Cl2, ETO, PH3, AsH3, SiH4, CO2, H2, NH3 sensors available.
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
Many chemicals are capable of causing a false positive
Start Up Time (From Cold Start To Sample Ready)
30 seconds
Response Time (Sample Application To Output)
<5 minutes; 30 to 90 seconds
Total Run Time
< 3 minutes
Alarm Capability
Visual and audible
Software Control
On-board, PC
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
1 year
Approved Vendors
Grainger; Hagemeyer; Orr Safety Corp.; Wilson Supply Co.