Sensepoint XCD Transmitter with Sensor

The Sensepoint XCD provides monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without needing to open the unit. A tri-color backlit LCD indicates the unit’s status. All detectors are supplied pre-configured and include 2 programmable alarm relays, 1 programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and MODBUS. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance. Sensepoint XCD uses poison resistant flammable sensors, poison immune infrared Hydrocarbon sensors and patented Surecell™ toxic sensors.

Notify me on updates of this product 

Availability: Commercially Available

+1 847 955 8200
405 Barclay Boulevard
Lincolnshire, IL 60069
www.honeywellanalytics.com/
Manufacturer
Honeywell Analytics
Product Name
Sensepoint XCD Transmitter with Sensor
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Catalytic Bead Sensor; Infrared (IR) Spectroscopy; Electrochemical Detection ;
Application
Gas Analysis;
Equipment Type
Sensor
Product Synopsis
The Sensepoint XCD provides monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without needing to open the unit. A tri-color backlit LCD indicates the unit’s status. All detectors are supplied pre-configured and include 2 programmable alarm relays, 1 programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and MODBUS. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance. Sensepoint XCD uses poison resistant flammable sensors, poison immune infrared Hydrocarbon sensors and patented Surecell™ toxic sensors.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
6.5 x 8.9 x 3.9 in (164 x 225 x 99 mm)
Weight
<30 lbs.; Aluminum Alloy LM25 4.4 lbs (2.0 kg) 316 Stainless Steel 11 lbs (5.0 kg)
Power Requirements
AC/DC Line Power; 16 to 32 VDC (24 VDC nominal)
Transportability
Pocket Size
Ruggedness
Extreme Temperatures/Humidity
Operating Conditions
-20 to 55°C (-4 to 131°F); 90 to 110 kPa Operating Pressure; 20 to 90%RH
Consumables
<$1,000/year; Replacement sensors
Available Accessories
Weatherproof cap, sunshade/deluge protection, duct mounting kit, collecting cone and remote mounting sensor socket
Communications Interface
RS485, MODBUS RTU (optional)
Unit Cost
$1,400.00
Maintenance Cost
Combustible and toxic sensors $450, IR sensor $625
Other Chemical Targets
Oxygen, Hydrogen Sulfide, Carbon Monoxide, Hydrogen, Nitrogen Dioxide, Flammable, Methane, Propane, Carbon Dioxide
Sample Introduction
Vapor/Gas
Response Time (Sample Application To Output)
<1 minute
Alarm Capability
Yes
Training Required
<1 week training
Manuals Available
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 