PhD6

The PHD6 is a multi-gas detector from Sperian Honeywell Analytics Instrumentation. It is a configurable detector, with 5 sensor ports, up to 6 channels of detection, and 18 sensor options including electrochemical, LEL, PID, and Infrared.

Notify me on updates of this product 

Availability: DISCONTINUED

Tom Kochevar
detectgas@honeywell.com
+1 877 723 2878
3775 North First Street
San Jose, CA 65134
USA
www.honeywellanalytics.com
Manufacturer
Honeywell Analytics
Product Name
PhD6
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Photoionization Detection; Electrochemical Detection;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The PHD6 is a multi-gas detector from Sperian Honeywell Analytics Instrumentation. It is a configurable detector, with 5 sensor ports, up to 6 channels of detection, and 18 sensor options including electrochemical, LEL, PID, and Infrared.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
6.63 x 3.13 x 2 in (17 x 8 x 5 cm)
Weight
<5 lbs.; 1 to 1.3 lbs (0.45 to 0.59 kg)
Power Requirements
Lithium Battery; Alkaline Battery; Rechargeable Li-ion or Alkaline (3XAA) battery pack options
Noise Produced
92 db
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP65
Operating Conditions
-18 to 43°C ( 0.4 to 109°F); 15 to 95% RH, non-condensing 1 LPM pump flow rate nominal
Consumables
<$1,000/year; Replacement Sensors, calibration gas
Calibration Schedule
Every 30 days
Available Accessories
IQ6 docking station, calibration kit
Data Analysis Support Equipment
PC
Communications Interface
IrDA port that allows the instrument to be configured with a PC.
Expected Operational Life
5+ years
Shelf Life
<5 years; Sensors last between 2 and 5 years
Unit Cost
$1,100.00
Maintenance Cost
Sensor replacement at least every 2 years $125 to $700
Tested For ITF-25 TIC/TIMs
Electrochemical sensors: carbon monoxide, hydrogen sulfide, sulfur dioxide, nitric oxide, nitrogen dioxide, hydrogen cyanide, phosphine, chlorine, chlorine dioxide, ammonia, methane, combustible gas, and oxygen. PID Sensor: Monitors for hundreds of known VOCs.
Other Chemical Targets
Measures O2, LEL, PID, Duo-Tox, CO, H2S, CO-H, SO2, Cl2, NO, NO2, NH3, PH3, HCN, IR-CO2, IR-CH4
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; ppb
Known Interferents/Inhibitors
CO sensors can false alarm from exposure to hydrogen and alcohol. LEL sensors are sensitive to silicone and could lose sensitivity to methane if exposed to silicone.
Start Up Time (From Cold Start To Sample Ready)
15 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); 15 seconds
Total Run Time
Continuous
Alarm Capability
Audible and visual
Software Control
IrDA port that allows the instrument to be configured with a PC.
Other Operational Parameters
Data logging
Training Required
<1 day training
Training Available
Training CD
Manuals Available
Operator’s manual
Warranties
2 year warranty. PID sensor has a 1 year warranty
IATA Shipping Restrictions
Calibration gas cylinder must be shipped per IATA restrictions for compressed gas.