MST Gas Sensors
Honeywell Analytics MST sensors are designed for use with the Satellite and Sat-Ex Series gas detectors. Sensors available include: methane, oxygen, phosphine, chlorine trifluoride, arsine, diborane, bromine, chlorine, chlorine dioxide, carbon monoxide, phosgene, fluorine, germane, hydrogen, hydrogen sulfide, hydrogen bromide, hydrogen chloride, hydrogen cyanide, hydrogen fluoride, hexamethyldisilazane, hydrazine, ammonia, nitric oxide, nitrogen dioxide, ozone, silane, sulfur dioxide, tetraethyl silicate, trimethyl borate, trimethyl phosphite.
Availability: Commercially Available
| Manufacturer |
| Honeywell Analytics |
| Product Name |
| MST Gas Sensors |
| Detection Category |
| Chemical |
| Detection Principle |
| Sensors; |
| Detection Method |
| Electrochemical Detection ; |
| Application |
| Emergency Response; Gas Analysis; |
| Equipment Type |
| Sensor |
| Product Synopsis |
| Honeywell Analytics MST sensors are designed for use with the Satellite and Sat-Ex Series gas detectors. Sensors available include: methane, oxygen, phosphine, chlorine trifluoride, arsine, diborane, bromine, chlorine, chlorine dioxide, carbon monoxide, phosgene, fluorine, germane, hydrogen, hydrogen sulfide, hydrogen bromide, hydrogen chloride, hydrogen cyanide, hydrogen fluoride, hexamethyldisilazane, hydrazine, ammonia, nitric oxide, nitrogen dioxide, ozone, silane, sulfur dioxide, tetraethyl silicate, trimethyl borate, trimethyl phosphite. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 0.84 x 1.69 in (22 x 43 mm) |
| Weight |
| <1 lb.; .32 x .99 oz (9-28 g) |
| Transportability |
| Pocket Size |
| Ruggedness |
| Extreme Temperatures/Humidity |
| Operating Conditions |
| -40 to 55°C (-40 to 131°F); 10 to 95%RH, non-condensing |
| Consumables |
| <$1,000/year; Calibration gas |
| Calibration Schedule |
| Yes |
| Tested For Chemical Agents |
| No |
| Tested For ITF-25 TIC/TIMs |
| Yes |
| Tested For Explosives |
| No |
| Tested For Narcotics |
| No |
| Other Chemical Targets |
| Methane, Oxygen, Phosphine, Chlorine trifluoride, Arsine |
| Sample Introduction |
| Vapor/Gas |
| Sensitivity/Detection Limits |
| ppm; %LEL; % |
| Known Interferents/Inhibitors |
| Sensor dependent |
| Start Up Time (From Cold Start To Sample Ready) |
| 5 seconds |
| Response Time (Sample Application To Output) |
| <1 minute; T(50)< 10 seconds based on 1 minute exposure time T(90)< 20 seconds based on 1 minute exposure time |
| Alarm Capability |
| No |
| Training Required |
| <1 hour training |
| Manuals Available |
| Yes |
| Warranties |
| 2 years |