Impact/Impact Pro
The Impact Series is a compact, portable gas monitor designed to be carried or worn by the user. Its purpose is to monitor the atmosphere continuously for hazardous levels of up to four gases. The instrument is usually supplied with four gas sensors, for detecting oxygen (enrichment and deficiency), flammable gases (up to the Lower Explosive Limit) and two toxic gases (for personal safety). An alternative arrangement using infrared sensors for flammable or carbon dioxide is also available.
Availability: DISCONTINUED
Manufacturer |
| Honeywell Analytics |
Product Name |
| Impact/Impact Pro |
Detection Category |
| Chemical |
Detection Principle |
| Molecular Spectroscopy; Sensors; |
Detection Method |
| Electrochemical Detection; Infrared (IR) Spectroscopy ; |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The Impact Series is a compact, portable gas monitor designed to be carried or worn by the user. Its purpose is to monitor the atmosphere continuously for hazardous levels of up to four gases. The instrument is usually supplied with four gas sensors, for detecting oxygen (enrichment and deficiency), flammable gases (up to the Lower Explosive Limit) and two toxic gases (for personal safety). An alternative arrangement using infrared sensors for flammable or carbon dioxide is also available. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 1.9 x 3.3 x 5.3 in (49 x 84 x 136 mm) |
Weight |
| <5 lbs.; 18.3 oz (520 g) |
Power Requirements |
| NiMH Battery; rechargeable, operating life > 10 hours (Charging time 7 hours). Dry cell disposable > 17 hours. Nominal reduction of 10% when used with pump. |
Transportability |
| Handheld |
Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock |
Operating Conditions |
| –20 to 55°C (–4 to 131°F); 20 to 90% RH |
Consumables |
| <$1,000/year; Cartridge replacement in less than one minute |
Solvents/Reagents |
| None |
Calibration Schedule |
| Yes, cartridge specific |
Suggested Routine Maintenance |
| Routine cleaning; Changing of filters; Battery replacement |
Available Accessories |
| Base Station; Flow Adapter; Metal Belt Clip; Earpiece; Sensing Probe; |
Data Analysis Support Equipment |
| Safelink Confined-Space Communications, PC |
Communications Interface |
| RS485 digital communication link with CAN line drivers |
Expected Operational Life |
| 5+ years |
Shelf Life |
| <6 months |
Unit Cost |
| $1,000.00 |
Maintenance Cost |
| Recommended that on a regular basis the instrument is cleaned and the filters changed |
Tested For Chemical Agents |
| No |
Tested For ITF-25 TIC/TIMs |
| H2S, Cl2, SO2 |
Tested For Explosives |
| No |
Tested For Narcotics |
| No |
Other Chemical Targets |
| Flammable gases |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm; %LEL; % |
Known Interferents/Inhibitors |
| Oxygen sensors may read high in the presence of carbon dioxide. Flammable sensors may be affected by exposure to Silicone substances; organic phosphorus containing compounds and halogenated organic compounds. The sensors on average will lose approximately 20% of their sensitivity when subjected to forty applications of H2S for a period of 1 minute each. |
Start Up Time (From Cold Start To Sample Ready) |
| < 70 seconds (250 seconds for NH3) |
Response Time (Sample Application To Output) |
| <5 minutes; 60 seconds ( 90 seconds for NH3) |
Alarm Capability |
| Audible and visual |
Software Control |
| Onboard software |
Other Operational Parameters |
| Various configurations can be modified via connected PC |
Training Required |
| <1 day training |
Training Available |
| On-site training can be customized to meet the needs of specific equipment, site application and attendees |
Manuals Available |
| User Manual |
Warranties |
| 24 months for unit, 12 months for sensors |
ITAR/EAR Export Regulations |
| Yes; Calibration gas cylinders are ground transport only |
IATA Shipping Restrictions |
| Yes; Calibration gas cylinders are ground transport only |