Gasmet DX4015

Gasmet™ DX4015 is a portable IR gas analyzer for ambient air analysis. The DX4015 is the oldest of the DX 4000 series. It is typically used in industrial hygiene and emergency situations. Up to 50 compounds can be measured simultaneously. The sample cell is heated to 50°C, which allows measurement to be done in conditions where high humidity is expected.

Notify me on updates of this product 

Availability: Commercially Available

Jim Cornish
Sales & Support Manager
jim.cornish@gasmet.com
+1 866 685 0050
956A The Queensway
Toronto, Ontario, M8Z 1P5
Canada
sales@gasmet.com
www.gasmet.com
Manufacturer
Gasmet Technologies, Inc.
Product Name
Gasmet DX4015
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Mid-infrared Spectroscopy;
Application
Gas Analysis;
Product Model Number
DX4015
Equipment Type
Instrument
Product Synopsis
Gasmet™ DX4015 is a portable IR gas analyzer for ambient air analysis. The DX4015 is the oldest of the DX 4000 series. It is typically used in industrial hygiene and emergency situations. Up to 50 compounds can be measured simultaneously. The sample cell is heated to 50°C, which allows measurement to be done in conditions where high humidity is expected.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
17.2 x 6.45 x 17.5 in (438 x 164 x 445 mm)
Weight
<50 Lbs.; 32.9 Lbs. (14.9 kg)
Power Requirements
AC/DC Line Power; Standard AC power: 100-115 V or 230 V / 50 -60 Hz
Transportability
Person-Portable
Ruggedness
None
Operating Conditions
Short term temperature: 0 to 40°C (32 to 150°F) Long term temperature: 5 to 30°C (41 to 86°F); 90%RH, non-condensing
Consumables
>$1,000/year; Nitrogen gas, 5.0 purity or higher
Solvents/Reagents
None
Calibration Schedule
Zero point calibration performed using nitrogen (4.0 or higher N2 recommended) immediately before sampling and no more than once every 24 hours
Data Analysis Support Equipment
Sample Cell Portable Sampling System Calibrator Pressure measurement: Inside sample cell Analog Signals (ext PC): ADAM 5000/TCP Sample cell gaskets: Teflon® coated Viton® or Kalrez® -Trolley: wheeled cart for the analyzer and laptop computer
Communications Interface
Bluetooth, RS232 Analyzer is connected to an external computer via RS- 232C cable. The external computer controls the instrument. The system operating software is CALCMET for Windows XP.
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$60,000.00
Tested For ITF-25 TIC/TIMs
Few
Other Chemical Targets
Volatile organic compounds, acids, aldehydes, and inorganic compounds such as CO, CO2, N2O
Adaptability
Yes; user can add new targets to detector with support
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppb; ppm
Start Up Time (From Cold Start To Sample Ready)
1 to 15 minutes
Response Time (Sample Application To Output)
<5 minutes; < 2 minutes
Total Run Time
<2 minutes
Alarm Capability
Yes
Software Control
PC; An external computer controls the GASMET through the operating software, “CALCMET” for Windows XP.
Other Operational Parameters
Simultaneous analysis of up to 50 gas compounds
Training Required
<1 day training
Training Available
Vendor training at customer or vendor facility
Manuals Available
Operator’s Manual Software Manual
Warranties
1 year