Gasmet DX4015
Gasmet™ DX4015 is a portable IR gas analyzer for ambient air analysis. The DX4015 is the oldest of the DX 4000 series. It is typically used in industrial hygiene and emergency situations. Up to 50 compounds can be measured simultaneously. The sample cell is heated to 50°C, which allows measurement to be done in conditions where high humidity is expected.
Availability: Commercially Available
| Manufacturer |
| Gasmet Technologies, Inc. |
| Product Name |
| Gasmet DX4015 |
| Detection Category |
| Chemical |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Mid-infrared Spectroscopy; |
| Application |
| Gas Analysis; |
| Product Model Number |
| DX4015 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| Gasmet™ DX4015 is a portable IR gas analyzer for ambient air analysis. The DX4015 is the oldest of the DX 4000 series. It is typically used in industrial hygiene and emergency situations. Up to 50 compounds can be measured simultaneously. The sample cell is heated to 50°C, which allows measurement to be done in conditions where high humidity is expected. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 17.2 x 6.45 x 17.5 in (438 x 164 x 445 mm) |
| Weight |
| <50 Lbs.; 32.9 Lbs. (14.9 kg) |
| Power Requirements |
| AC/DC Line Power; Standard AC power: 100-115 V or 230 V / 50 -60 Hz |
| Transportability |
| Person-Portable |
| Ruggedness |
| None |
| Operating Conditions |
| Short term temperature: 0 to 40°C (32 to 150°F) Long term temperature: 5 to 30°C (41 to 86°F); 90%RH, non-condensing |
| Consumables |
| >$1,000/year; Nitrogen gas, 5.0 purity or higher |
| Solvents/Reagents |
| None |
| Calibration Schedule |
| Zero point calibration performed using nitrogen (4.0 or higher N2 recommended) immediately before sampling and no more than once every 24 hours |
| Data Analysis Support Equipment |
| Sample Cell Portable Sampling System Calibrator Pressure measurement: Inside sample cell Analog Signals (ext PC): ADAM 5000/TCP Sample cell gaskets: Teflon® coated Viton® or Kalrez® -Trolley: wheeled cart for the analyzer and laptop computer |
| Communications Interface |
| Bluetooth, RS232 Analyzer is connected to an external computer via RS- 232C cable. The external computer controls the instrument. The system operating software is CALCMET for Windows XP. |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $60,000.00 |
| Tested For ITF-25 TIC/TIMs |
| Few |
| Other Chemical Targets |
| Volatile organic compounds, acids, aldehydes, and inorganic compounds such as CO, CO2, N2O |
| Adaptability |
| Yes; user can add new targets to detector with support |
| Sample Introduction |
| Vapor/Gas |
| Sensitivity/Detection Limits |
| ppb; ppm |
| Start Up Time (From Cold Start To Sample Ready) |
| 1 to 15 minutes |
| Response Time (Sample Application To Output) |
| <5 minutes; < 2 minutes |
| Total Run Time |
| <2 minutes |
| Alarm Capability |
| Yes |
| Software Control |
| PC; An external computer controls the GASMET through the operating software, “CALCMET” for Windows XP. |
| Other Operational Parameters |
| Simultaneous analysis of up to 50 gas compounds |
| Training Required |
| <1 day training |
| Training Available |
| Vendor training at customer or vendor facility |
| Manuals Available |
| Operator’s Manual Software Manual |
| Warranties |
| 1 year |