GasMet DX4030
DISCONTINUED - Gasmet™ DX4030 is an IR gas analyzer for ambient air analysis. It is designed for applications where up to 25 compounds need to be monitored in ambient air. Examples include leakage detection and various industrial hygiene applications (monitoring of VOC’s, TIC’s, anesthetic gases, etc.). It’s also suited for first response/HAZMAT type applications.
Availability: DISCONTINUED
Manufacturer |
| Gasmet Technologies, Inc. |
Product Name |
| GasMet DX4030 |
Detection Category |
| Chemical |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Mid-infrared Spectroscopy; |
Application |
| Gas Analysis; Emergency Response; |
Equipment Type |
| Instrument |
Product Synopsis |
| DISCONTINUED - Gasmet™ DX4030 is an IR gas analyzer for ambient air analysis. It is designed for applications where up to 25 compounds need to be monitored in ambient air. Examples include leakage detection and various industrial hygiene applications (monitoring of VOC’s, TIC’s, anesthetic gases, etc.). It’s also suited for first response/HAZMAT type applications. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 16 x 24 x 6 in (40.6 x 61 x 15.3 cm) |
Weight |
| <30 lbs.; 25.4 lbs (11.5 kg) |
Power Requirements |
| Lithium Battery; AC/DC Line Power; Battery and 120 VAC—2.5 hours on battery |
Transportability |
| Person-Portable |
Ruggedness |
| None; Not militarized, drop sensitive |
Operating Conditions |
| 5 to 30°C (41 to 86°F) |
Consumables |
| >$1,000/year; Supply of Inert Gas for Zero calibration (if zeroing on non-contaminated air is not possible). Recommend :103L cylinder with 2-3 L/m flow regulator. Particulate Filters - Changed each 6 months or sooner if testing in high dust conditions |
Calibration Schedule |
| Zero calibration |
Data Analysis Support Equipment |
| Hand-held PDA unit |
Communications Interface |
| RS-232 Bluetooth USB |
Shelf Life |
| <5 years; 4 years |
Unit Cost |
| $34,990.00 |
Tested For ITF-25 TIC/TIMs |
| Yes |
Other Chemical Targets |
| Organics, Inorganics |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| Bulk; mg; g |
Known Interferents/Inhibitors |
| Cross-interferences (i.e. interference from other gases) are automatically compensated in the analysis algorithm |
Start Up Time (From Cold Start To Sample Ready) |
| < 15 minutes |
Response Time (Sample Application To Output) |
| <5 minutes; < 120 Seconds |
Alarm Capability |
| Audible |
Software Control |
| PDA |
Other Operational Parameters |
| 8 cm–1 resolution 10 Scans/sec Spectral range: 900 to 4,200 cm–1 |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| 1 year |