X-am 5000 Series
The Dräger X-am 5000 is 1 to 5 gas detector that measures combustible gases and vapors as well as O2 and harmful concentrations of Cl2, CO, CO2, H2, H2S, HCN, NH3, NO, NO2, PH3, SO2 and organic vapors. Uses proprietary miniaturized EC sensors, referred to as XXS sensors in Dräger sales literature. The X-am 5100 is a single gas detector for gases HF, HCl, H2O2 or hydrazine.
Availability: Commercially Available
+1 800 437 2437
7256 South Sam Houston Parkway, Suite 100
Houston, TX 77085
USA
|
+49 451 8841
Moislinger Allee 53-76
23579 Lübeck
Germany
|
www.draeger.com
| Manufacturer |
| Dräger Safety, Inc. |
| Product Name |
| X-am 5000 Series |
| Detection Category |
| Chemical |
| Detection Principle |
| Sensors |
| Detection Method |
| Electrochemical Detection |
| Application |
| Emergency Response; Gas Analysis; |
| Product Model Number |
| X-am 5000, X-am 5100 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The Dräger X-am 5000 is 1 to 5 gas detector that measures combustible gases and vapors as well as O2 and harmful concentrations of Cl2, CO, CO2, H2, H2S, HCN, NH3, NO, NO2, PH3, SO2 and organic vapors. Uses proprietary miniaturized EC sensors, referred to as XXS sensors in Dräger sales literature. The X-am 5100 is a single gas detector for gases HF, HCl, H2O2 or hydrazine. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Hands-on experience |
| Dimensions |
| 1.85 x 5.08 x 1.22 (47 x 129 x 31 mm) |
| Weight |
| <1 Lb.; 7.8 oz (220 g) |
| Power Requirements |
| Alkaline Battery; Rechargeable Alkaline (greater than 12 hours, > 40 hours in save energy mode) |
| Transportability |
| Handheld |
| Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock; IP67, Integrated rubber protection and shock-proof sensors ensure additional resistance to impact and vibration |
| Operating Conditions |
| –30 to 50°C (–20 to 120°F); 10 to 90% RH |
| Consumables |
| <$1,000/year; Sensing elements, Optional calibration kits |
| Calibration Schedule |
| Every 6 months |
| Available Accessories |
| Charging accessories Pump accessories Communication accessories Case Calibration accessories |
| Communications Interface |
| USB |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| <5 years; 2 years |
| Unit Cost |
| $1,500.00 |
| Tested For ITF-25 TIC/TIMs |
| HF, HCl, H2O2, hydrazine |
| Other Chemical Targets |
| combustible gases and vapors as well as O2 and harmful concentrations of Cl2, CO, CO2, H2, H2S, HCN, NH3, NO, NO2, PH3, SO2 and organic vapors |
| Sample Introduction |
| Vapor/Gas |
| Sensitivity/Detection Limits |
| ppm |
| Known Interferents/Inhibitors |
| Compensates for hydrogen interference up to 2,000 ppm |
| Start Up Time (From Cold Start To Sample Ready) |
| < 5 minutes |
| Response Time (Sample Application To Output) |
| <1 minute |
| Total Run Time |
| Continuous |
| Alarm Capability |
| Audible, visual and vibrational |
| Training Required |
| <1 day training |
| Training Available |
| Yes, operator training CD |
| Manuals Available |
| Yes |
| Warranties |
| 3 years |