PAC 7000
The Dräger PAC 7000 can only detect a single gas, but Drager offers units for 12 specific chemicals (see below). The PAC 7000 utilizes XXS electrochemical detectors.
Availability: Commercially Available
+1 800 437 2437
7256 South Sam Houston Parkway, Suite 100
Houston, TX 77085
USA
|
+49 451 8836
Moislinger Allee 53-71
23574 Lübeck
Germany
|
www.draeger.com
Manufacturer |
| Dräger Safety, Inc. |
Product Name |
| PAC 7000 |
Detection Category |
| Chemical |
Detection Principle |
| Sensors |
Detection Method |
| Electrochemical Detection |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The Dräger PAC 7000 can only detect a single gas, but Drager offers units for 12 specific chemicals (see below). The PAC 7000 utilizes XXS electrochemical detectors. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 3.3 × 2.5 × 1.0 in (84 × 64 × 25 mm) |
Weight |
| <1 Lb.; 3.8 oz (120 g) |
Power Requirements |
| Lithium Battery; 5,500 hours |
Transportability |
| Handheld |
Ruggedness |
| Extreme Temperatures/Humidity; Dust; Waterproof/Resistant; Vibration/Shock; metal-plated ABS housing, shock-proof, IP65 specs |
Operating Conditions |
| –30 to 50°C (–20 to 120°F); 10 to 90% RH |
Consumables |
| <$1,000/year; Sensing element, water & dust filters |
Calibration Schedule |
| Yes- fresh air, calibration gas following malfunction or replacement |
Suggested Routine Maintenance |
| Minimal – filter replacement |
Available Accessories |
| Software Kit Calibration Adapter |
Communications Interface |
| USB connection, IR |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Unit Cost |
| $425.00 |
Maintenance Cost |
| Minimal |
Tested For ITF-25 TIC/TIMs |
| Carbon monoxide, hydrogen sulfide, oxygen, carbon dioxide, sulfur dioxide, chlorine, hydrogen cyanide, ammonia, nitrogen dioxide, nitrogen monoxide, phosphine and organic vapors. Each target chemical requires a separate unit. |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm |
Start Up Time (From Cold Start To Sample Ready) |
| 20 seconds |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Alarm Capability |
| Audible and visual |
Software Control |
| On-board |
Training Required |
| <1 day training |
Manuals Available |
| Yes |
Warranties |
| 5 year optional |
ITAR/EAR Export Regulations |
| Yes; None for unit itself, calibration gas cylinders likely require ground transport only. |
IATA Shipping Restrictions |
| Yes; None for unit itself, calibration gas cylinders likely require ground transport only. |