Multi-PID 2

The Dräger Multi-PID 2 is a photoionization detector for volatile organic compounds (VOCs). Equipped with a standard 10.6 eV UV lamp the Dräger Multi-PID 2 covers a measuring range from 0 to 2,000 ppm. An optional dilution probe extends the measuring range up to 20,000 ppm. The Multi PID 2 has up to 70 substances saved in the device with capacity for up to 60 more.

Notify me on updates of this product 

Availability: DISCONTINUED

+1 800 437 2437
7256 South Sam Houston Parkway, Suite 100
Houston, TX 77085
USA
+49 451 8835
Moislinger Allee 53-70
23573 Lübeck
Germany
www.draeger.com
Manufacturer
Dräger Safety, Inc.
Product Name
Multi-PID 2
Detection Category
Chemical
Detection Principle
Sensors
Detection Method
Photoionization Detection
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The Dräger Multi-PID 2 is a photoionization detector for volatile organic compounds (VOCs). Equipped with a standard 10.6 eV UV lamp the Dräger Multi-PID 2 covers a measuring range from 0 to 2,000 ppm. An optional dilution probe extends the measuring range up to 20,000 ppm. The Multi PID 2 has up to 70 substances saved in the device with capacity for up to 60 more.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
9 x 4.25 x 3 in (22.9 x 10.8 x 7.6 cm)
Weight
<5 Lbs.; 1.9 Lbs. (0.860 kg)
Transportability
Handheld
Operating Conditions
Susceptible to extreme temperatures. High humidity could cause instrument malfunction
Calibration Schedule
Performed by the user before each use
Suggested Routine Maintenance
Lamp needs to be changed periodically. 10.6 V lamp $469.
Communications Interface
Gas vision software
Shelf Life
<6 months; 3 to 6 months
Unit Cost
$4,450.00
Maintenance Cost
469
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
The built-in gas library holds up to 70 substances. Another 60 substances are identified and can be substituted in the library.
Tested For Explosives
Not Specified
Other Chemical Targets
The built-in gas library holds up to 70 substances. Another 60 substances are identified and can be substituted in the library.
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Start Up Time (From Cold Start To Sample Ready)
10 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Alarm Capability
Audible and visual
Software Control
The data logging feature allows the operator to record 15,000 sampling points which can be downloaded to a PC.
Training Required
<1 day training
Training Available
Training manual
Manuals Available
Operator's manual and technical manual