Miniwarn Gas Detector

MiniWarn is a small, lightweight, and ergonomically shaped personal multi-gas monitor for continuous and simultaneous detection of up to four gases in ambient air. MiniWarn is compatible with over 25 electrochemical sensors for toxic gases and a catalytic sensor for combustible gases.

Notify me on updates of this product 

Availability: DISCONTINUED

+1 800 437 2437
7256 South Sam Houston Parkway, Suite 100
Houston, TX 77085
USA
+49 451 8834
Moislinger Allee 53-69
23572 Lübeck
Germany
www.draeger.com
Manufacturer
Dräger Safety, Inc.
Product Name
Miniwarn Gas Detector
Detection Category
Chemical
Detection Principle
Sensors
Detection Method
Electrochemical Detection
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
MiniWarn is a small, lightweight, and ergonomically shaped personal multi-gas monitor for continuous and simultaneous detection of up to four gases in ambient air. MiniWarn is compatible with over 25 electrochemical sensors for toxic gases and a catalytic sensor for combustible gases.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
3.1 × 5.6 × 2.3 in (79 x 142 x 58 mm)
Weight
<1 Lb.; < 0.5 kg
Power Requirements
NiMH Battery; NiCd rechargeable battery
Transportability
Handheld
Ruggedness
Vibration/Shock; Extreme Temperatures/Humidity; The MiniWarn Gas Detector is constructed of a high impact resistant composite material.
Operating Conditions
–20 to 40°C (–4 to 104°F); 10 to 95% RH
Consumables
>$1,000/year; Calibration kit, batteries, and sensors (for each chemical detected)
Solvents/Reagents
None
Calibration Schedule
Every 3 to 6 months
Suggested Routine Maintenance
Replacement of sensors and other maintenance as required by manufacturer
Available Accessories
Calibration adapter, sample pump, and battery charger
Communications Interface
All stored measurements are transferred to a PC via a wireless infrared interface
Shelf Life
<5 years; 6 months to 3 years
Unit Cost
$2,534.00
Maintenance Cost
Up to $590 to replace a sensor
Tested For Chemical Agents
No
Tested For ITF-25 TIC/TIMs
Ammonia, arsine, chlorine, diborane, fluorine, hydrogen cyanide, hydrogen sulfide, phosgene, sulfur dioxide, carbon monoxide, hydrogen selenide, phosphine, nitrogen dioxide, nitrogen oxide, amines, carbon dioxide, hydrogen, and mercaptans.
Tested For Explosives
No
Other Chemical Targets
No
Adaptability
No; cannot detect or add new targets
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
May false alarm due to heavy concentrations of various smokes and engine exhausts
Start Up Time (From Cold Start To Sample Ready)
30 to 60 seconds
Response Time (Sample Application To Output)
<1 minute; 10 to 60 seconds
Alarm Capability
Audible and Visual
Training Required
<1 day training
Training Available
Yes
Manuals Available
User manual
Warranties
5 years
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: