CMS Analyzer
The Chip Measurement System (CMS) Analyzer is a digitized colorimetric kit designed to detect select hazardous chemicals. TWA levels are typically analyzed in 1 to 2 minutes. Upon completion of the analysis, concentration is indicated on the LCD display.
Availability: Commercially available
+1 800 437 2437
7256 South Sam Houston Parkway, Suite 100
Houston, TX 77805
USA
|
|
www.draeger.com
| Manufacturer |
| Dräger Safety, Inc. |
| Product Name |
| CMS Analyzer |
| Detection Category |
| Chemical; Explosives |
| Detection Principle |
| Colorimetric |
| Detection Method |
| Colorimetric |
| Application |
| Emergency Response; Screening; Bulk Analysis; Trace Analysis; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The Chip Measurement System (CMS) Analyzer is a digitized colorimetric kit designed to detect select hazardous chemicals. TWA levels are typically analyzed in 1 to 2 minutes. Upon completion of the analysis, concentration is indicated on the LCD display. |
| Availability |
| Commercially available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Hands-on experience |
| Dimensions |
| 12 × 15 × 8 in (305 x 381 x 203 mm) |
| Weight |
| <30 Lbs.; 10 Lbs. (4.5 kg) |
| Power Requirements |
| Alkaline Battery; 4 AA batteries; 100 measurements per charge |
| Transportability |
| Person-Portable |
| Ruggedness |
| Vibration/Shock |
| Operating Conditions |
| 0 to 40°C (32 to 104°F) up to 95% RH |
| Consumables |
| >$1,000/year; Analysis chips are one-time use only |
| Calibration Schedule |
| Performed at factory |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| <5 years; 2 years |
| Unit Cost |
| $4,330.00 |
| Maintenance Cost |
| $109 for annual recommended calibration |
| Tested For ITF-25 TIC/TIMs |
| Formaldehyde, hydrogen chloride, phosphine, phosgene, chlorine, ammonia, hydrogen sulfide, HCN, methyl mercaptan, vinyl chloride, and others |
| Other Chemical Targets |
| Detectable chemicals are available on vendor website |
| Sample Introduction |
| Vapor/Gas |
| Sensitivity/Detection Limits |
| ppm |
| Known Interferents/Inhibitors |
| Potential false positives |
| Start Up Time (From Cold Start To Sample Ready) |
| 10 seconds |
| Response Time (Sample Application To Output) |
| <15 minutes; 30 seconds to 10 minutes |
| Total Run Time |
| <15 minutes; 30 seconds to 10 minutes |
| Software Control |
| Handheld digital analyzer stores up to 50 results |
| Training Required |
| <1 day training |
| Training Available |
| Training CDs |
| Manuals Available |
| Operator's manual |
| Reachback Service |
| No |
| Warranties |
| 1 year |
| ITAR/EAR Export Regulations |
| No |
| IATA Shipping Restrictions |
| No |