795 System
The 795 is specifically for Carbon Monoxide; however, it belongs to a class of sensors from Delphian called Common Sensors which have a part prefix of 365.
Availability: Commercially Available
Manufacturer |
| Delphian Corporation |
Product Name |
| 795 System |
Detection Category |
| Chemical |
Detection Principle |
| Sensors; |
Detection Method |
| Electrochemical Detection ; |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Sensor |
Product Synopsis |
| The 795 is specifically for Carbon Monoxide; however, it belongs to a class of sensors from Delphian called Common Sensors which have a part prefix of 365. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 8 x 6 in (204 x 153 mm) |
Weight |
| <1 lb.; 0.5 lbs (.23 kg) |
Power Requirements |
| AC/DC Line Power; Digital Controller requires 24 VDC Analog Controller options 24 VDC or 115 VAC |
Transportability |
| Pocket Size |
Operating Conditions |
| -5 to 40°C |
Consumables |
| <$1,000/year; Source could be damaged and sensor cells need replacement |
Calibration Schedule |
| Yes |
Suggested Routine Maintenance |
| Minimal |
Data Analysis Support Equipment |
| Flame Arrestor, Analog and Digital Controllers Available, Controllers require a Flexirack system to house the controller |
Communications Interface |
| Digital Controller has an output relay Analog Controller has a 4-20 mA output |
Shelf Life |
| >5 years; IR sensors last 10 years, catalytic bead 3 years, electrochemical 2 years |
Unit Cost |
| $405.00 |
Maintenance Cost |
| Electrochemical sensor cells $259 |
Other Chemical Targets |
| Carbon monoxide |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm |
Known Interferents/Inhibitors |
| Electrochemical cells are vulnerable to organic solvents. |
Start Up Time (From Cold Start To Sample Ready) |
| Variable, the cell must be biased for a stable output and depending on the temperature could be up to 8 hours. |
Response Time (Sample Application To Output) |
| <5 minutes; Usually less than 90 seconds to 90% |
Alarm Capability |
| Yes |
Software Control |
| Yes, but separately from system |
Training Required |
| <1 week training |
Training Available |
| Courses are usually available every 3 months |
Manuals Available |
| Yes |
Warranties |
| 2 years for system |