ACEM 9350

The ACEM 9350 Captures compounds of interest on adsorbent material packed in glass cartridges and then introduce the chemicals into a GC system. The CDS 9350 is the latest real time air monitoring system. It has been designed to deal with the more difficult environments that have to date, not been achievable. This includes the ability to collect and analyze compounds with boiling points down to -50º C, without cryogen trapping or cryofocusing, and collect analytes with boiling points above 300º C with a sampling line and all heated zones capable of maintaining temperatures of up to 350º C. The CDS 9350 has fast flow capabilities for sample collection of up to 1.5 LPM, rapid heat and cool down times for both sorbent tubes and focus trap without the need for cryo focusing. This allows for much quicker cycle times, from collection to completion of analytical analysis, when utilizing the latest in Low Thermal Mass (LTM) chromatography techniques.

Notify me on updates of this product 

Availability: Commercially Available

+1 610 932 4158
465 Limestone Road, PO Box 277
Oxford, PA 19363-0277
USA
www.cdsanalytical.com
Manufacturer
CDS Analytical, Inc.
Product Name
ACEM 9350
Detection Category
Chemical; Explosives
Detection Principle
Chromatography;
Detection Method
Gas Chromatography; Flame Photometric Detection (FPD);
Application
Laboratory Analysis; Trace Analysis; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The ACEM 9350 Captures compounds of interest on adsorbent material packed in glass cartridges and then introduce the chemicals into a GC system. The CDS 9350 is the latest real time air monitoring system. It has been designed to deal with the more difficult environments that have to date, not been achievable. This includes the ability to collect and analyze compounds with boiling points down to -50º C, without cryogen trapping or cryofocusing, and collect analytes with boiling points above 300º C with a sampling line and all heated zones capable of maintaining temperatures of up to 350º C. The CDS 9350 has fast flow capabilities for sample collection of up to 1.5 LPM, rapid heat and cool down times for both sorbent tubes and focus trap without the need for cryo focusing. This allows for much quicker cycle times, from collection to completion of analytical analysis, when utilizing the latest in Low Thermal Mass (LTM) chromatography techniques.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
10.5 x 9.25 x 12.5 in (267 x 235 x 317.5 mm)
Weight
<50 lbs.; (22.7 kg)
Power Requirements
AC/DC Line Power; 120 V AC
Transportability
Benchtop/Fixed
Operating Conditions
Designed for use in a controlled environment 59° to 95°F.
Consumables
<$1,000/year; Sorbent materials
Suggested Routine Maintenance
Minimal
Communications Interface
Wireless LAN interface with ChemStation allows for remote operation
Shelf Life
>5 years; Product lifetime indefinite with routine maintenance
Unit Cost
$25,000.00
Maintenance Cost
$1,000 - $2,000 per year
Tested For Chemical Agents
GA, GB, GD, GF, VX, HD, HN, L tested on similar MSD systems. Other CWA also tested
Tested For ITF-25 TIC/TIMs
Most organic compounds
Tested For Explosives
Most organic compounds
Other Chemical Targets
Applicable to all organic compounds amenable to GC
Adaptability
Yes
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppt
Known Interferents/Inhibitors
GC/MS is a highly selective technique for identification of organic compounds when used by a skilled operator, with low false positive/negative rates for target analytes. False IDs are more likely for unknowns (non-targets) since GC retention times cannot be compared to reference RTs. Additional selectivity for CWAs provided by FPD detector (sensitive to P and S only).
Start Up Time (From Cold Start To Sample Ready)
30 minutes
Response Time (Sample Application To Output)
>15 minutes; 5-45 minutes
Alarm Capability
Visual
Software Control
Agilent ChemStation data acquisition software
Other Operational Parameters
Entire system is mounted on a steel plate for moving from a fixed laboratory to a mobile platform. Entire sample pathway is closed; no effluent gases can escape from any components into the atmosphere during analysis.
Training Required
<1 day training
Training Available
Yes
Manuals Available
Operator’s manual on CD