Aegis 1000
The Aegis 1000 immunoassay has an enhanced target-analyte capture efficiency due to an extremely high surface-area-to-volume ratio. Reagents are supplied in a self-contained, disposable cartridge with built-in valving and flow cell. The instrument provides quantitative results for six simultaneous assays. The Aegis 1000 was designed for food testing, clinical diagnosis and environmental monitoring.
Availability: DISCONTINUED
| Manufacturer |
| BioDetection Instruments (BDI) |
| Product Name |
| Aegis 1000 |
| Detection Category |
| Biological |
| Detection Principle |
| Immunological; |
| Detection Method |
| Lateral Flow Hand Held Immunoassay ; |
| Application |
| Emergency Response; Detection; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The Aegis 1000 immunoassay has an enhanced target-analyte capture efficiency due to an extremely high surface-area-to-volume ratio. Reagents are supplied in a self-contained, disposable cartridge with built-in valving and flow cell. The instrument provides quantitative results for six simultaneous assays. The Aegis 1000 was designed for food testing, clinical diagnosis and environmental monitoring. |
| Availability |
| DISCONTINUED |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Supporting Documentation |
| Docs: BDI - AEGIS.pdf; |
| Dimensions |
| 12 x 8.5 x 12 in (305 x 216 x 305 mm) |
| Weight |
| <30 lbs.; 12 lbs. (5 kg) |
| Power Requirements |
| AC/DC Line Power; Rechargeable battery pack External power supply: 24 V DC, 4 A Output, 110-220 VAC |
| Transportability |
| Handheld |
| Consumables |
| <$1,000/year; Cartridges containing six channels, reagents |
| Solvents/Reagents |
| Yes; included in disposable sampling cartridges |
| Communications Interface |
| USB |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $8,000.00 |
| Tested For Biological Agents |
| Yes |
| Other Biological Targets |
| Foodborne pathogens, toxins, infectious agents, protein biomarkers, waterborne pathogens |
| Sample Introduction |
| Liquid |
| Sensitivity/Detection Limits |
| cfu/mL; Biomarkers: pg/mL range in 30 minutes Bacteria: 1,000 CFU/mL in 1 hour, single cell detection in one workday |
| Response Time (Sample Application To Output) |
| <15 minutes; Concentration dependent |
| Total Run Time |
| < 30 minutes |
| Alarm Capability |
| No |
| Software Control |
| On-board PC |
| Training Required |
| <1 week training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |