SBG-200 Wall-Mounted Gas Monitor

A semi-conductor is applied to a non-conductor between two electrodes. The system is heated to a point where the gas of interest will cause a change in the conductivity of the semi-conductor. As the concentration of the gas of interest increases, the resistance of the semi-conductor drops. A relay contact is provided to allow the SBG-200 to connect with a central alarm system or turn on emergency apparatus.

Notify me on updates of this product 

Availability: Commercially Available

contact@amgas.com
+1 800 288 3647
220 Pegasus Avenue
Northvale, NJ 07647
USA
www.amgas.com
Manufacturer
American Gas & Chemical Company
Product Name
SBG-200 Wall-Mounted Gas Monitor
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection ;
Application
Emergency Response; Gas Analysis;
Equipment Type
Sensor
Product Synopsis
A semi-conductor is applied to a non-conductor between two electrodes. The system is heated to a point where the gas of interest will cause a change in the conductivity of the semi-conductor. As the concentration of the gas of interest increases, the resistance of the semi-conductor drops. A relay contact is provided to allow the SBG-200 to connect with a central alarm system or turn on emergency apparatus.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
6.75 x 4.875 x 2 in (172 x 124 x 51 mm)
Weight
<5 lbs.; 2 lbs (.91 kg)
Power Requirements
AC/DC Line Power; Can be ordered to plug into a standard 110 V outlet or ordered for 12/24 VDC.
Transportability
Benchtop/Fixed
Operating Conditions
50-90°F, 30-70% RH
Consumables
<$1,000/year; Calibration gas
Calibration Schedule
Yes, initial calibration is used to set the alarm level performed by the manufacturer
Data Analysis Support Equipment
Optional chart recorder and sensor extension wire. Also optional sound and light alarm.
Communications Interface
Relay Circuit
Unit Cost
$945.00
Maintenance Cost
Calibration cost ~$100
Other Chemical Targets
Yes, see table at the bottom of survey for list of commonly detected chemicals with detection levels
Sample Introduction
Vapor/Gas
Known Interferents/Inhibitors
Electrochemical cells are vulnerable to organic solvents. Catalytic beads are poisoned by silicones, fluorides and chlorides. IR has little to no interferences, but cannot see hydrogen.
Start Up Time (From Cold Start To Sample Ready)
If powered off for a long time, the sensor oxidizes, it will take a full hour to warm up. If used regularly, it will warm up within seconds.
Response Time (Sample Application To Output)
Continuous (<30 seconds); 12 seconds (the alarm activates after reading an alarm condition for 12 seconds)
Alarm Capability
Yes, sound and light alarm
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
Yea, 1 year limited