4100 ExoScan Series
The 4100 ExoScan™ is a portable, hand-held, battery operated FTIR analyzer designed to measure a wide variety of solid and liquid samples. The instrument contains interchangeable ATR and external reflectance sample interfaces, a PDA based control panel that wirelessly links to a laptop for upload and download of data, methods etc., multi-level software and user interfaces, and a docking station allows the Exoscan to be used in a lab similar to a benchtop FTIR.
Availability: DISCONTINUED
Manufacturer |
| Agilent Technologies |
Product Name |
| 4100 ExoScan Series |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Mid-infrared Spectroscopy; |
Application |
| Emergency Response; Screening; Bulk Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The 4100 ExoScan™ is a portable, hand-held, battery operated FTIR analyzer designed to measure a wide variety of solid and liquid samples. The instrument contains interchangeable ATR and external reflectance sample interfaces, a PDA based control panel that wirelessly links to a laptop for upload and download of data, methods etc., multi-level software and user interfaces, and a docking station allows the Exoscan to be used in a lab similar to a benchtop FTIR. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
Market Entry Date |
| July 2013 |
User Feedback Sources |
| MRIGlobal hands-on experience |
Supporting Documentation |
| Docs: Agilent - 4100 Exoscan series.pdf; |
Dimensions |
| Infrared Module: 6.75 × 4.69 × 8.81 in (171.5 × 118.9 × 223.8 mm); PDA: 5.00 × 2.94 × 0.81 in (127 × 74.60 × 20.6 mm) |
Weight |
| <30 lbs.; Infrared Module: 7 lbs (3.18 kg); PDA: 6.3 oz (178.60 g) |
Power Requirements |
| Lithium Battery; Rechargeable (3.2 hours Infrared module, 8 hours PDA module) |
Noise Produced |
| None |
Transportability |
| Handheld |
Ruggedness |
| Waterproof/Resistant; Vibration/Shock; Withstands 40G on each axis (in shipping case); Withstands 60 Hz vibration for 30 minutes |
Operating Conditions |
| 0 to 50°C (32 to 122°F) |
Consumables |
| <$1,000/year; Dessicant cartridges |
Calibration Schedule |
| Quarterly performance verification |
Suggested Routine Maintenance |
| Minimal; external cleaning, software updates |
Communications Interface |
| Wireless LAN IEEE® 802.11 b/g Antenna: Internal; Bluetooth v2.0 +EDR Class 2 Supported; USB |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Unit Cost |
| $46,000.00 |
Maintenance Cost |
| Minimal |
Tested For Chemical Agents |
| Amenable based on technology |
Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
Tested For Explosives |
| Amenable based on technology |
Tested For Narcotics |
| Amenable based on technology |
Other Chemical Targets |
| Amenable based on technology |
Number of Library Entries |
| Not Specified |
Sample Introduction |
| Solid; Liquid |
Sensitivity/Detection Limits |
| Bulk; mg; g |
Known Interferents/Inhibitors |
| Successful identification of an unknown is dependent on the presence of the corresponding reference spectrum in the library. Analysis of mixtures can produce erroneous search results unless the library contains a reference spectrum of the mixture itself. |
False Positive Rates |
| <1% |
False Negative Rates |
| <1% |
Start Up Time (From Cold Start To Sample Ready) |
| 5 minutes (30 minutes prior to performance tests) |
Response Time (Sample Application To Output) |
| <5 minutes; Sample dependent |
Software Control |
| On-board software |
Other Operational Parameters |
| Michelson interferometer, 4 cm–1 resolution; Frequency range: 650 to 4,000 cm-1 |
Training Required |
| <1 day training |
Training Available |
| Yes, 1 day |
Manuals Available |
| Yes |
Warranties |
| 1 year |
ITAR/EAR Export Regulations |
| No |
IATA Shipping Restrictions |
| Yes; Li-ion battery |