identiFINDER® R440

The FLIR identiFINDER R440 is a lightweight, sourceless radioisotope identification device (RIID) that can be operated with one hand. The extended energy range provides neutron indication. It is IP67-rated and drop-tested to 1m. The new 360° EasyFinder™ mode collects and interprets data..

Notify me on updates of this product 

Availability: Commercially Available

Julie Bazzell
Distribution & Sales Coordination Manager, Detection
julie.bazzell@flir.com
+1 877 692 2120
27700 SW Parkway Avenue
Wilsonville, OR 97070
The Americas, EMEA, APAC
Contact for pricing, availability and 3rd party vendors
www.flir.com/threatdetection
Manufacturer
FLIR Systems, Inc.
Product Name
identiFINDER® R440
Detection Category
Radiological/Nuclear;
Detection Principle
Scintillation Detectors;
Detection Method
Scintillation Detectors;
Application
Identifiers;
Product Model Number
R440
Equipment Type
Instrument
Product Synopsis
The FLIR identiFINDER R440 is a lightweight, sourceless radioisotope identification device (RIID) that can be operated with one hand. The extended energy range provides neutron indication. It is IP67-rated and drop-tested to 1m. The new 360° EasyFinder™ mode collects and interprets data..
Availability
Commercially Available
Technology Readiness Level (TRL)
8
Market Entry Date
October 2017
User Feedback Sources
Hands-on experience
Dimensions
< 4 x 10.6 x 3.7 in (10.2 x 26.9 x 9.4 cm) - with battery
Weight
< 3.2 lbs (1.5 kg)
Power Requirements
12 hour Li-ion battery life, 4 hour AA battery life, 5 hour NiMH battery life
Transportability
Handheld
Durability
Rugged aluminum housing; protection rating IP67 according to IEC 60529; drop-tested to 1m
Operating Conditions
-20 to 50°C (-4 to 122 °F), 10 to 80 % RH
Consumables
None
Calibration Schedule
Automatic calibration on start up; Automated sourceless gain stabilization (patents pending)
Suggested Routine Maintenance
1 year factory maintenance suggested, not required
Available Accessories
Belt holster, battery holder, USB cable
Data Analysis Support Equipment
Software
Communications Interface
USB 2.0, USB OTG; Bluetooth® Class 2.0, 10m range (removable); WiFi 802.11 g/n
Expected Operational Life
10+ years
Shelf Life
10 years
Radiological Targets
Gamma, Neutron; SNM, IND, MED, NORM
Number of Library Entries
Nuclide identification according to ANSI N42.34
Customize For New Targets
No
Sample Introduction
Particle
Sensitivity/Detection Limits
Gamma Sensitivity (Cs-137, NaI) 1850 cps/µSv/h
Start Up Time (From Cold Start To Sample Ready)
< 2 minutes
Response Time (Sample Application To Output)
Seconds to minutes
Total Run Time
Continuous
Alarm Capability
Transflective color LCD with visual, audible, tacticle alarms
Software Control
On-board webserver software
Other Operational Parameters
Dose Rate Range: 10nSv/h - 10mSv/h (1µrem/h - 1rem/h) / ±30 %; Energy Range (Gamma): 10 keV to 10 MeV; Typical resolution less than or equal to 7% FWHM at 662 keV with NaI detector at 20 °C
Operator Skills Required
<10 mins for operator; 1 day for advanced user
Training Available
Multiple options available including on-site, at manufacturer
Manuals Available
Yes
Reachback Service
Built-in Bluetooth and WiFi (removable at factory at request)
Warranties
1 year
ITAR Export Regulations
These products are controlled for export under US Department of Commerce (DOC), Export Administration Regulations (EAR). U.S. Government authorization may be required.
IATA Shipping Restrictions
Li-ion battery restrictions
Data File Type Format
32GB internal memory; ANSI N42.42 file format
Please enter contact info.
Email Address: 
Company: 
Name: 