Agentase™ C1 (Formerly Fido C1 CAD Kit)

Agentase™ C1 is a chemical agent detection kit (formerly named Fido C1 CAD KIT) that uses enzyme-based technology to detect class-specific chemical warfare agent (CWA) and selected other toxic chemical contamination on a variety of surfaces at trace level. Emergency responders use the Agentase™ C1 sensors to conduct surface, solid and liquid interrogation for the presence of nerve (G&V series), blood (AC) and blister (HD) agents, acids, bases, aldehydes and oxidizers. The Agentase™ C1 kit is provided in a small carry pouch weighing less than 1 lb and contains six sensors, which can be custom-configured for the emergency response mission requirement. The sensors do not destroy the sample and can be saved for eventual forensic analysis. The kit also includes a tool specifically designed to handle bulk samples. The Agentase™ C1 sensors detect trace levels of hazards and are resistant to common environmental interferents. Detection occurs within 5 minutes.

Notify me on updates of this product 

Availability: Commercially Available

Markus Erbeldinger
Product Manager, Detection
markus.erbeldinger@flir.com
+1 412 298 4807
2240 William Pitt Way
Pittsburgh, PA 15238
The Americas, EMEA, APAC
Contact for additional product specs and application questions
Julie Bazzell
Distribution & Sales Coordination Manager, Detection
detection@flir.com
+1 877 692 2120
27700 SW Parkway Avenue
Wilsonville, OR 97070
The Americas, EMEA, APAC
Contact for pricing, availability and 3rd party vendors
www.flir.com/threatdetection
Manufacturer
FLIR Systems, Inc.
Product Name
Agentase™ C1 (Formerly Fido C1 CAD Kit)
Detection Category
Chemical
Detection Principle
Colorimetric;
Detection Method
Colorimetric;
Application
Emergency Response; Forensics;
Product Model Number
Multiple Based on Selected Options - Not Specified
Equipment Type
Wet Chemistry
Product Synopsis
Agentase™ C1 is a chemical agent detection kit (formerly named Fido C1 CAD KIT) that uses enzyme-based technology to detect class-specific chemical warfare agent (CWA) and selected other toxic chemical contamination on a variety of surfaces at trace level. Emergency responders use the Agentase™ C1 sensors to conduct surface, solid and liquid interrogation for the presence of nerve (G&V series), blood (AC) and blister (HD) agents, acids, bases, aldehydes and oxidizers. The Agentase™ C1 kit is provided in a small carry pouch weighing less than 1 lb and contains six sensors, which can be custom-configured for the emergency response mission requirement. The sensors do not destroy the sample and can be saved for eventual forensic analysis. The kit also includes a tool specifically designed to handle bulk samples. The Agentase™ C1 sensors detect trace levels of hazards and are resistant to common environmental interferents. Detection occurs within 5 minutes.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
2010
User Feedback Sources
Military CBRNE teams & Local law enforcement HAZMAT squads
Dimensions
9 x 5 x 2 in (22.9 x 12.7 x 5.1 cm)
Weight
< 1.0 lb (0.5 kg)
Transportability
Handheld
Durability
Rugged
Operating Conditions
Storage Temp: Store at room temp out of direct sunlight; Time/temp indicators for storage conditions
Consumables
This product is one-time use only.
Expected Operational Life
One-time use only.
Shelf Life
2 years
Unit Cost
$250.00
Tested For Chemical Agents
Nerve agents (G and V series), blood agents (AC), blister agents (HD)
Tested For ITF-25 TIC/TIMs
Strong acid/bases, aldehydes, oxidizers
Customize For New Targets
No
Sample Introduction
Solid; Liquid
Sensitivity/Detection Limits
The enzyme sensors detect trace levels of hazards. The performance has been validated in 3rd party government tests. The sensitivity on surfaces is single micrograms (nerve agents), hundreds of micrograms (blister agents), tens of micrograms (blood agents) and tens of micrograms (TICs). Specific detection limits are subject to export restrictions and may only be disclosed to authorized parties in accordance with applicable U.S. export regulations.
Known Interferents/Inhibitors
Not Specified
Start Up Time (From Cold Start To Sample Ready)
<1 minute
Response Time (Sample Application To Output)
< 5 minutes
Total Run Time
<1 minute
Alarm Capability
Visual
Operator Skills Required
Non-technical background
Training Available
On-site training < 5 mins; no special skills required; instructional videos available
Manuals Available
Yes
Reachback Service
No
Warranties
Standard 1 Year Warranty included; Extended Warranty options are available, Not Specified
ITAR Export Regulations
These products are controlled as defense articles for export from the United States under the authority of the US Department of State, United States Munitions List (USML). US Government authorization is required for export from the United States to all destinations, whether for permanent or temporary export.
IATA Shipping Restrictions
Subject to IATA regulations