microAnalyzer V2.0

The microAnalyzer V2.0 is an ultra-trace (low parts per trillion (ppt)) portable chemical detection system based upon the orthogonal separation and detection technologies of Differential Mobility Spectrometry (DMS) and fast Gas Chromatography (GC). The microAnalyzer V2.0 may be programmed (on-unit or remotely) to accommodate different or addition methods to detect new compounds of interest. Coupled with various front end devices, the unit may analyze solids and liquids in addition to vapor.

Notify me on updates of this product 

Availability: Discontinued

Kenneth Markoski
kmarkoski@draper.com
+1 617 258 2387
555 Technology Square
Cambridge, MA 02139-3563
USA
Rob Larson
rlarson@draper.com
+1 617 258 1863
www.draper.com/solution/differential-mobility-spectrometry-dms
www.draper.com
Manufacturer
Draper
Product Name
microAnalyzer V2.0
Detection Category
Chemical; Explosives;
Detection Principle
Spectrometry; Chromatography;
Detection Method
Differential Ion Mobility Spectrometry (DMS); Gas Chromatography;
Application
Emergency Response; Gas Analysis; Laboratory Analysis; Screening; Trace Analysis;
Equipment Type
Instrument
Product Synopsis
The microAnalyzer V2.0 is an ultra-trace (low parts per trillion (ppt)) portable chemical detection system based upon the orthogonal separation and detection technologies of Differential Mobility Spectrometry (DMS) and fast Gas Chromatography (GC). The microAnalyzer V2.0 may be programmed (on-unit or remotely) to accommodate different or addition methods to detect new compounds of interest. Coupled with various front end devices, the unit may analyze solids and liquids in addition to vapor.
Availability
Discontinued
Technology Readiness Level (TRL)
9
Supporting Documentation
Docs: Draper-microAnalyzer V2.pdf;
Dimensions
10 x 6 x 5.2 in (25.4 x 15.3 x 13.4 cm)
Weight
6.6 lbs (3 kg)
Power Requirements
AC
Transportability
Person-Portable
Durability
Rugged
Operating Conditions
0 to 50°C (32 to 122°F)
Consumables
Filter cartridges
Suggested Routine Maintenance
Replace filter cartridges 1 to 2 times per year as needed.
Data Analysis Support Equipment
Via unit or connection with PC
Communications Interface
WiFi, RS232, USB, RJ45 Ethernet network connection
Expected Operational Life
10 years
Shelf Life
7 years
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes
Other Chemical Targets
Volatile Organic Compounds (VOCs), Liquids & solids with appropriate front end
Number of Library Entries
Not Specified
Customize For New Targets
Yes - Programmable method
Sample Introduction
Solid; Liquid; Vapor/Gas
Sensitivity/Detection Limits
ppt
Known Interferents/Inhibitors
Not Specified
Start Up Time (From Cold Start To Sample Ready)
Not Specified
Response Time (Sample Application To Output)
5 to 10 minutes depending on application
Total Run Time
30 minutes
Alarm Capability
Audible and Visual
Software Control
Autonomous, remote and/or PC interface
Other Operational Parameters
Parameters can be modified by the user
Operator Skills Required
Non-technical
Training Available
Yes
Manuals Available
Yes
Reachback Service
Not Specified
Warranties
1 year
ITAR Export Regulations
Not Specified
IATA Shipping Restrictions
Not Specified
Data File Type Format
TXT, XLS
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: