2HA Analog Portable Photometer

The 2HA is an Aerosol Detector. There are two models the 2HA is for chemical compounds and the 2HAN is for nuclear compounds.

Notify me on updates of this product 

Availability: Commercially Available

Tim McDiarmid
Technical Sales
tmcdiarmid@atitest.com
+1 410 363 9696
11403 Cronridge Drive
Owings Mills, MD 21117
USA
www.atitest.com
Manufacturer
Air Techniques International
Product Name
2HA Analog Portable Photometer
Detection Category
Chemical; Radiological/Nuclear
Detection Principle
Photometry;
Detection Method
Light-scattering;
Application
Emergency Response; Gas Analysis; Detection;
Product Model Number
2HA and 2HAN (nuclear)
Equipment Type
Accessory
Product Synopsis
The 2HA is an Aerosol Detector. There are two models the 2HA is for chemical compounds and the 2HAN is for nuclear compounds.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Dimensions
10.1 x 14.3 x 5.8 in (25.6 x 36.3 x 14.7 cm)
Weight
18 lbs (8 kg)
Power Requirements
100-250 V AC, 50/60 Hz
Transportability
Person-Portable
Durability
Rugged
Operating Conditions
Not Specified
Consumables
Pump Filter
Solvents/Reagents
Not Specified
Calibration Schedule
Yes, periodically
Suggested Routine Maintenance
Virtually maintenance-free
Available Accessories
Scanning Probe, Shipping/Storage Case
Data Analysis Support Equipment
None
Communications Interface
DB9
Expected Operational Life
50,000 to 100,000 hours (Light Source)
Shelf Life
Indefinite
Maintenance Cost
Not Specified
Tested For Chemical Agents
Not Specified
Tested For ITF-25 TIC/TIMs
Not Specified
Tested For Explosives
Not Specified
Tested For Narcotics
Not Specified
Other Chemical Targets
PAO-4, DOP, Ondina, PEG, Krydol, Corn Oil, Mineral Oil, Paraffin, Aerosol agents in air
Number of Library Entries
Not Specified
Customize For New Targets
Not Specified
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
100 to 0.0001 on 5 linear scales
Known Interferents/Inhibitors
Not Specified
Start Up Time (From Cold Start To Sample Ready)
Not Specified
Response Time (Sample Application To Output)
Not Specified
Total Run Time
Continuous
Alarm Capability
Audible and visual
Other Operational Parameters
Not Specified
Operator Skills Required
Non-technical background
Training Available
Yes
Manuals Available
User's manual
Reachback Service
Not Specified
Warranties
Not Specified
ITAR Export Regulations
Not Specified
IATA Shipping Restrictions