3200

The 3200 offers accurate ultrapure water analysis, multipoint calibration, and a high/low alarm for process applications. It measures conductivity, resistivity, salinity, total dissolved solids and temperature. Using Resistance Ratio TechnologyTM (RRT), the 3200 continually compares the resistance of the sample to a calibrated resistor in the circuit.

Notify me on updates of this product 

Availability: Commercially Available

environmental@ysi.com
+1 937 767 7241
1700/1725 Brannum Lane
Yellow Springs, OH 45387
USA
www.ysi.com
Manufacturer
YSI, Inc.
Product Name
3200
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Water Quality;
Application
Water Quality;
Equipment Type
Sensor
Product Synopsis
The 3200 offers accurate ultrapure water analysis, multipoint calibration, and a high/low alarm for process applications. It measures conductivity, resistivity, salinity, total dissolved solids and temperature. Using Resistance Ratio TechnologyTM (RRT), the 3200 continually compares the resistance of the sample to a calibrated resistor in the circuit.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Dimensions
9 x 9.5 x 4.4 in (229 x 242 x 112 mm)
Weight
2.6 lbs (1.2 kg)
Power Requirements
AC 115 V, 220 V
Transportability
Handheld
Durability
Designed for laboratory use
Operating Conditions
95% relative humidity, non-condensing
Consumables
Mainly conductivity cells and calibration solutions. manual lists 22 accessories or replacement parts that may be purchased according to the operator’s application.
Calibration Schedule
Yes
Suggested Routine Maintenance
Minimal
Data Analysis Support Equipment
The Operator’s Manual lists 22 accessories or replacement parts that may be purchased according to the operator’s application.
Communications Interface
RS-232
Unit Cost
$1,675.00
Maintenance Cost
conductivity cells $300 to $600
Other Chemical Targets
Measures conductivity, resistivity, salinity, total dissolved solids, and temperature
Sample Introduction
Liquid
Sensitivity/Detection Limits
ppt
Known Interferents/Inhibitors
Error sources: Absorption of atmospheric CO2, electrical noise, contact resistance, platinization, algae growth, and galvanic effects
Start Up Time (From Cold Start To Sample Ready)
<5 minutes
Response Time (Sample Application To Output)
5 seconds
Alarm Capability
Yes
Software Control
Is capable of datalogging to a computer or serial printer through ProCommTM or WindowsTM terminal.
Operator Skills Required
Technician
Manuals Available
Yes
Warranties
2 year instrument, 1 year cell and cables
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: