TVA 1000B Toxic Vapor Analyzer

The Thermo Scientific TVA 1000B is an over-the-shoulder portable vapor analyzer that offers both PID (Photoionization Detection) and FID (Flame Ionization Detection) in a single, instrument. The user can monitor and log inorganic and organic vapors simultaneously.

Notify me on updates of this product 

Availability: DISCONTINUED

+1 978 642 1132
46 Jonspin Road
Wilmington, MA 01887
USA
www.thermoscientific.com
Manufacturer
Thermo Fisher Scientific, Inc.
Product Name
TVA 1000B Toxic Vapor Analyzer
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Photoionization Detection; Flame Ionization Detection (FID) ;
Application
Emergency Response; Gas Analysis;
Product Model Number
Multiple
Equipment Type
Instrument
Product Synopsis
The Thermo Scientific TVA 1000B is an over-the-shoulder portable vapor analyzer that offers both PID (Photoionization Detection) and FID (Flame Ionization Detection) in a single, instrument. The user can monitor and log inorganic and organic vapors simultaneously.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
Dimensions
13.5 × 10.3 × 3.2 in (343 × 262 × 81 mm)
Weight
13 lbs (5.8 kg)
Power Requirements
Rechargeable NiCd Battery
Transportability
Person-Portable
Durability
Rugged
Operating Conditions
0 to 40°C (32 to 104°F)
Consumables
Hydrogen gas, batteries, and calibration gas
Calibration Schedule
Yes, a calibration kit with a gas cylinder can be purchased with the instrument for daily calibration.
Available Accessories
Carrying case, charcoal filter, FID calibration kit, PID/FID calibration kit, and bluetooth communication module
Communications Interface
Data logger software is included
Expected Operational Life
8 hours
Shelf Life
If purchased, a PID could need replacement after a year or two, depending on exposure to contaminates
Unit Cost
$9,829.00
Maintenance Cost
Gas and battery replacement as needed. Est: <$200 per year
Tested For Chemical Agents
Some
Tested For ITF-25 TIC/TIMs
Yes, VOCs
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppb
Known Interferents/Inhibitors
Alarms to hydrocarbon fumes
Start Up Time (From Cold Start To Sample Ready)
15 to 20 minutes depending upon surrounding temperatures
Response Time (Sample Application To Output)
3.5 seconds
Alarm Capability
Audible and visual
Other Operational Parameters
Has data logging onboard
Operator Skills Required
Non-technical background
Training Available
2 to 3 hours online training
Manuals Available
Operator’s manual
Warranties
1 year with extended warranties available
IATA Shipping Restrictions
Calibration gas cylinder must be shipped per IATA restrictions for compressed gas.