RIIDEye M Series

The Thermo Scientific RIIDEye™ Handheld Radiation Isotope Identifier uses Quadratic Compression Conversion (QCC) technology to provide real-time gamma source, dose rate, isotope identification and spectral analysis. It provides source data during and after completion of ID. The LCD screen has an easy-to-read, full-spectrum color-coded format. The RIIDEye™ is designed for operation in any environment or scenario. M-G3 Model has a 3 x 3 in NaI detector.

Notify me on updates of this product 

Availability: Commercially Available

Denny Cannon
+1 303 907 0324
27 Forge Parkway
Franklin, MA 02038
USA
www.thermoscientific.com
Manufacturer
Thermo Fisher Scientific, Inc.
Product Name
RIIDEye M Series
Detection Category
Radiological/Nuclear
Detection Principle
Scintillation Detectors;
Detection Method
Scintillation Detectors;
Application
Identifiers;
Product Model Number
M-G3, M-HN, M-G, M-GN, M-H
Equipment Type
Instrument
Product Synopsis
The Thermo Scientific RIIDEye™ Handheld Radiation Isotope Identifier uses Quadratic Compression Conversion (QCC) technology to provide real-time gamma source, dose rate, isotope identification and spectral analysis. It provides source data during and after completion of ID. The LCD screen has an easy-to-read, full-spectrum color-coded format. The RIIDEye™ is designed for operation in any environment or scenario. M-G3 Model has a 3 x 3 in NaI detector.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Dimensions
12.6 x 9.8 x 5.8 in. (32 x 25 x 15 cm)
Weight
RIIDEye M: 5.1 lbs (2.3 kg)
Power Requirements
AA batteries (8 hours)
Transportability
Handheld
Durability
Rugged
Operating Conditions
-20 to 50°C (-4 to 122°F)
Suggested Routine Maintenance
Not Specified
Available Accessories
Optional dual scintillator with imbedded Lithium, Gamma neutron pager
Data Analysis Support Equipment
Not Specified
Communications Interface
Removable memory card, Ethernet and serial data interface
Expected Operational Life
Indefinite
Shelf Life
10 years
Unit Cost
$9,220.00 to $26,000
Maintenance Cost
Minimal
Radiological Targets
Gamma, Neutron
Number of Library Entries
47 isotopes with 6 different trigger lists including ANSI, ANSI+, Security, Medical industrial
Customize For New Targets
Not Specified
Sample Introduction
Particle;
Sensitivity/Detection Limits
20 keV to 3 MeV
Known Interferents/Inhibitors
Not Specified
Start Up Time (From Cold Start To Sample Ready)
Seconds to minutes
Response Time (Sample Application To Output)
Seconds
Total Run Time
Continuous
Alarm Capability
Audible and Visual
Software Control
On-board, PC
Other Operational Parameters
Not Specified
Operator Skills Required
Non-technical
Training Available
Yes
Manuals Available
Operator’s Manual
Reachback Service
Not Specified
Warranties
1 year
ITAR Export Regulations
Not Specified
IATA Shipping Restrictions
Not Specified
Data File Type Format
Not Specified
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: