HGVI

The product can identify and quantify TICs and CWAs using data from three on-board sensor technologies: IMS, PID, and EC.

Notify me on updates of this product 

Availability: DISCONTINUED

+1 410 612 2625
2202 Lakeside Boulevard
Edgewood, MD 21040
USA
www.smithsdetection.com
Manufacturer
Smiths Detection, Inc.
Product Name
HGVI
Detection Category
Chemical; Explosives;
Detection Principle
Spectrometry; Sensors;
Detection Method
Ion Mobility Spectrometry (IMS); Photoionization Detection (PID); Electrochemical Detection (EC);
Application
Emergency Response; Gas Analysis; Screening; Trace Analysis; Bulk Analysis;
Equipment Type
Instrument
Product Synopsis
The product can identify and quantify TICs and CWAs using data from three on-board sensor technologies: IMS, PID, and EC.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
Dimensions
17 x 5.5 x 5.0 in (432 x 140 x 127 mm)
Weight
7.5 lbs (3.4 kg)
Power Requirements
Rechargeable Lithium Ion battery, system operates for 8 hours on 1 fully-charged battery, 18 V DC; 110/240 V AC, cigarette power lighter adaptor, alkaline battery pack
Transportability
Handheld
Durability
Somewhat durable; designed for first response applications. Operates in extreme weather temperature range
Operating Conditions
–10 to 50°C( –14 to 122°F)
Consumables
Air purification cartridges need to be changed every 300 hr of operation.
Calibration Schedule
Can be performed by the user up to the point of a unit failure, which would require factory assistance.
Data Analysis Support Equipment
Laptop included only with the remote monitoring package purchase.
Communications Interface
USB
Shelf Life
10 years
Unit Cost
$26,600.00
Maintenance Cost
Average cost ~ $300 per year
Tested For Chemical Agents
Yes: Nerve, Blister, Blood and Choking agents
Tested For ITF-25 TIC/TIMs
Yes: High and Medium Hazard materials from the ITF-25 list
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
Start Up Time (From Cold Start To Sample Ready)
10 to 15 minutes
Response Time (Sample Application To Output)
5 seconds
Alarm Capability
Audible, visual, and vibrational
Software Control
Yes, and a laptop is included if the remote monitoring package is purchased.
Other Operational Parameters
Also responds to gamma radiation and identifies about 20 of the high and medium hazard TICs from the ITF-25 list.
Operator Skills Required
Non-technical background
Training Available
Instructional video and regional training. Onsite training is included with the remote monitoring package.
Manuals Available
Operator’s manual
Warranties
1 to 4 years., depending on selected package
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: