ETK-210, Pocket ETK-FN

The Explosives Test Kit (ETK-210) detects a wide range of explosive targets with a hand-held kit. The kit utilizes colorimetric methods of wiping a suspect surface and applying various reagents to the wipe. The kits are able to detect a variety of HME, identifying each class of energetic compounds based on color change. Pocket ETK kits are also available for single mission use.

Notify me on updates of this product 

Availability: Commercially Available

Lindsay Pettinelli
lpettinelli@lindongroup.com
+1 401 272 2081
245 Waterman Street, Suite 109
Providence, RI 02906
USA
www.lindongroup.com
Manufacturer
Lindon Defense
Product Name
ETK-210, Pocket ETK-FN
Detection Category
Chemical; Explosives
Detection Principle
Colorimetric;
Detection Method
Colorimetric;
Application
Emergency Response; Screening; Bulk Analysis; Trace Analysis;
Equipment Type
Wet Chemistry
Product Synopsis
The Explosives Test Kit (ETK-210) detects a wide range of explosive targets with a hand-held kit. The kit utilizes colorimetric methods of wiping a suspect surface and applying various reagents to the wipe. The kits are able to detect a variety of HME, identifying each class of energetic compounds based on color change. Pocket ETK kits are also available for single mission use.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Dimensions
ETK 250 :9.5 x 6.5 x 3.5 in (24 x 17 x 9 cm) Pocket ETK: 2.8 x 2.8 x 1.2 in (7 x 7 x 3 cm)
Weight
26 oz (567 g)
Power Requirements
Batteries
Transportability
Pocket Size
Durability
Rugged
Operating Conditions
4 to 35°C (39 to 95°F)
Consumables
Reagent ampules, wipes
Solvents/Reagents
Reagent ampules
Expected Operational Life
150 tests
Shelf Life
1 year, reagent ampules expire 2 weeks after breaking
Unit Cost
$400.00
Tested For Explosives
TNT, RDX, HMX, PETN, Chlorates/Perchlorates, AN, CAN Tetryl, TNB, Picric Acid, Nitrocellulose smokeless powders, C4, SEMTEX, TATP
Other Chemical Targets
Ammonium & Urea nitrate
Sample Introduction
Solid; Liquid
Sensitivity/Detection Limits
ng; µg
Known Interferents/Inhibitors
Can produce false-positives on fresh nitrocellulose-based paints
Start Up Time (From Cold Start To Sample Ready)
<1 minute
Response Time (Sample Application To Output)
40 seconds
Total Run Time
< 1 minute
Operator Skills Required
Non-technical background
Training Available
No
Manuals Available
Yes
Reachback Service
Not Specified
Warranties
Not Specified
ITAR Export Regulations
Not Specified
IATA Shipping Restrictions
Not Specified
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: