MicroFID II

The MicroFID II Flame Ionization Detector (FID) is a portable instrument designed for HAZMAT detection, confined space entry and soil gas monitoring. MicroFID II provides measurements over a wide range of VOCs, including methane. Its operating range of 0.1 ppm to 50,000 ppm helps define the severity of a hot zone. MicroFID II allows up to 70 hours of continuous use at very low pressure (80 psi) to maximize field operation up-time. Typical applications include chemical incident response, arson accelerant investigations, soil gas monitoring and petroleum products tank entry.

Notify me on updates of this product 

Availability: Discontinued

(315) 434-2580
Two Technology Place
East Syracuse, NY 13057
USA
www.inficon.com
Manufacturer
INFICON
Product Name
MicroFID II
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Flame Ionization Detection (FID);
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The MicroFID II Flame Ionization Detector (FID) is a portable instrument designed for HAZMAT detection, confined space entry and soil gas monitoring. MicroFID II provides measurements over a wide range of VOCs, including methane. Its operating range of 0.1 ppm to 50,000 ppm helps define the severity of a hot zone. MicroFID II allows up to 70 hours of continuous use at very low pressure (80 psi) to maximize field operation up-time. Typical applications include chemical incident response, arson accelerant investigations, soil gas monitoring and petroleum products tank entry.
Availability
Discontinued
Technology Readiness Level (TRL)
9
Dimensions
13 x 12 x 3 in (331 x 305 x 77 mm)
Weight
11 lbs (5 kg)
Power Requirements
Nickel Metal Hydride (NiMH) battery, 15 hour use/charge
Transportability
Person-Portable
Durability
Rugged
Operating Conditions
0 to 50°C (32 to 122°F); 0 to 100% RH, non-condensing
Consumables
Sample Bag, ALTEF, 1L or 3L, Polymer, Septum Hydrogen fuel cylinder Exhaust frit and housing replacement Fluoropore filters Calibration gas Hydrogen fuel
Solvents/Reagents
Not Specified
Calibration Schedule
With each start up: Zero point calibration and span gas calibration must be done just prior to each day’s analysis
Suggested Routine Maintenance
ProCare annual service $486
Available Accessories
Hydrostik Adapter Kit; Battery Charger; Gas Bag Adapter; Sample probe; Charcoal Filters; Coalescing Filters; Calibration Gas Regulator
Data Analysis Support Equipment
Handheld device (computer, PDA or mobile phone)
Communications Interface
Detection data may be displayed on an optional PDA and uploaded to a PC through its built-in Bluetooth wireless interface.
Expected Operational Life
10+ years
Shelf Life
Dependent on calibration gas shelf life, which varies depending on the gas used. Gases must be replaced before expiration.
Unit Cost
$11,495.00
Maintenance Cost
$486 every year
Tested For Chemical Agents
No
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
No
Tested For Narcotics
No
Other Chemical Targets
Volatile organic compounds
Number of Library Entries
Not Specified
Customize For New Targets
Not Specified
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
Not Specified
Start Up Time (From Cold Start To Sample Ready)
20 minute warm up
Response Time (Sample Application To Output)
90% of full scale in < 3 seconds
Total Run Time
Not Specified
Alarm Capability
Audible and Visual
Software Control
Integrates with LeakDAS® Mobile and GuideWare monitoring software
Other Operational Parameters
Not Specified
Operator Skills Required
Non-technical
Training Available
Vendor training at customer or vendor facility
Manuals Available
Operator’s Manual
Reachback Service
Not Specified
Warranties
1 year warranty, extended warranty available
ITAR Export Regulations
FCC regulated: Class B digital device, pursuant to Subpart B, Class B of Part 15 of the FCC rules -Intrinsically safe within North American UL standards: Class 1, Division 1, Groups A, B, C, and D (UL913) -IATA regulations apply for the fuel cylinder and calibration gases
IATA Shipping Restrictions
FCC regulated: Class B digital device, pursuant to Subpart B, Class B of Part 15 of the FCC rules -Intrinsically safe within North American UL standards: Class 1, Division 1, Groups A, B, C, and D (UL913) -IATA regulations apply for the fuel cylinder and calibration gases
Data File Type Format
Not Specified
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: