ChemProDM

The ChemProDM is a detector module that uses open loop IMS technology for fixed applications where local user interface and built-in rechargeable battery are not needed. The Detector Module is controlled via RS-232/485 serial communications. The ChemProDM samples continuously and does not need a clear-down mode which can interrupt sampling.

Notify me on updates of this product 

Availability: Commercially Available

Timo Jaakkola
timo.jaakkola@environicsusa.com
+358 201 430 493
Sammonkatu 12, PL 349
50101 Mikkeli
Finland
www.environicsusa.com
Manufacturer
Environics Oy
Product Name
ChemProDM
Detection Category
Chemical; Explosives;
Detection Principle
Spectrometry;
Detection Method
Ion Mobility Spectrometry ;
Application
Emergency Response; Gas Analysis; Screening;
Equipment Type
Instrument
Product Synopsis
The ChemProDM is a detector module that uses open loop IMS technology for fixed applications where local user interface and built-in rechargeable battery are not needed. The Detector Module is controlled via RS-232/485 serial communications. The ChemProDM samples continuously and does not need a clear-down mode which can interrupt sampling.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
2010
Dimensions
5.1 x 3.5 x 2.4 in (13 x 9 x 6 cm)
Weight
2.2 lbs (1 kg)
Power Requirements
Vehicle power: 9 to 36 VDC
Transportability
Benchtop/Fixed
Durability
Rugged, MIL-STD-461E and 810E compliant and weatherproof
Operating Conditions
-30 to 55°C (-22 to 131°F)
Calibration Schedule
Confidence check only
Suggested Routine Maintenance
Filters and pumps
Data Analysis Support Equipment
PC, software
Communications Interface
RS-232/485
Expected Operational Life
Indefinite
Shelf Life
5 years
Unit Cost
$13,000.00
Maintenance Cost
Minimal
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes
Other Chemical Targets
Storage for up to 20 libraries with 50 compounds each
Customize For New Targets
New libraries can be downloaded to the device via serial port by using a PC-based user interface program.
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Start Up Time (From Cold Start To Sample Ready)
60 to 90 seconds
Response Time (Sample Application To Output)
4 to 60 seconds
Total Run Time
Continuous
Alarm Capability
Yes
Software Control
PC
Operator Skills Required
Non-technical background
Training Available
Yes
Manuals Available
Yes
Warranties
5 year
ITAR Export Regulations
Department of Commerce (SNAP-R) regulates and restricts shipping to certain countries. ECCN# 1A004
IATA Shipping Restrictions
Department of Commerce (SNAP-R) regulates and restricts shipping to certain countries. ECCN# 1A004